background image

 

 

léÉê~íáçå=~åÇ=fåëí~ää~íáçå=j~åì~ä==

bclv=mêç=pÉêáÉë=

=
=

=

d_

=

Summary of Contents for EFOY Pro 1200

Page 1: ...l f j bclv m p d_...

Page 2: ...ion 11 3 1 Integrated user interface 11 3 2 Remote Control 12 3 3 Select Language 14 3 4 Remote Control with Computer 14 3 5 Connecting the Fuel Cartridge 15 3 6 Automatic Operation 17 3 7 Switching O...

Page 3: ...r 33 6 6 Electrical Connection to the Battery 34 6 7 Combination with other energy sources 37 6 8 Connecting the Remote Control 38 7 Data Interface and Accessories 40 7 1 Data Interface Functionality...

Page 4: ...the installation instructions Please contact our sales partner where you have bought the product in case you have questions about installation or operation Manufacturer s address SFC Smart Fuel Cell...

Page 5: ...here there is no danger of freezing or use the automatic antifreeze feature see Chapter 3 9 Do not smoke when handling the unit or the fuel cartridges Keep away from heat and open flame There is a dan...

Page 6: ...accident or if nausea occurs consult a physician immediately Be sure to bring the fuel cartridge label or these instructions to the consultation A caution concerning methanol can be found in the appe...

Page 7: ...tended for emergency medical power generation or for powering life sustaining or agricultural devices The parallel operation of units to increase the charging current is possible The serial operation...

Page 8: ...ng protects your unit during shipping All materials used are environmentally compatible and recyclable We recommend saving the packaging for eventual winter storage Danger of Suffocation Keep packagin...

Page 9: ...dge holder with belt Mounting plate for EFOY Pro Exhaust hose Charge line Service Fluid User manual 2 2 System Overview 1 Charge line connection 2 Remote control connection 3 Data interface 4 Push but...

Page 10: ...Storage temperature 1 C to 45 C 34 F to 113 F Recommended altitude Up to 1500 m 4920 ft Dimensions L x W x H 433 x 188 x 278 mm 17 x 8 x 11 in Inclination along the roll axis Permanent max 35 tempora...

Page 11: ...sh button is used to control the unit Push button action Result Starting state Resulting state Push shortly 0 5s Reset On Off or Automatic Automatic On or Automatic Off Push longer 3s Switch On off Of...

Page 12: ...available network cable Cat 5 patch cable 1 Display 2 Information button and language selection button 3 On Off button 4 Button for automatic operation auto 5 Yellow warning light Please change fuel...

Page 13: ...rs 500 h Total operating hours Automatic Standby Standard display The standard display will be restored after about 30 seconds Alternatively you can return to the standard display by pressing again Au...

Page 14: ...ory setting English French Italian Dutch Spanish Continue pressing until the desired language appears Then hold 2 more seconds in order to set your language choice 3 4 Remote Control with Computer It...

Page 15: ...available methanol may cause permanent damage to the unit and may void the warranty Note When the cartridge is empty Please change fuel cartridge will appear on the remote control and the yellow light...

Page 16: ...connector onto the new fuel cartridge Press reset on the control panel to extinguish the yellow warning light and the maintenance message Notes For mobile applications the fuel cartridge needs to be p...

Page 17: ...note that the device interrupts power generation briefly several times an hour during normal operation and a charging power of 0 0 A is displayed then Automatic Charging mode The second line of the di...

Page 18: ...elf and will only charge if the battery or the demand for power requires it 3 8 Switching Off manually Press on the remote control to switch off the device The unit will gradually shut down performing...

Page 19: ...ode will appear on the second line The first line will indicate the current operating mode for example Off The antifreeze function works only as long as a fuel cartridge and a sufficiently intact batt...

Page 20: ...clean Keep unit and fuel cartridges even empty or partially empty cartridges away from children Remove the exhaust hose Keep it clean and place a cap over the exhaust outlet Remove the off heat tube...

Page 21: ...r yourself The unit is maintenance free under normal operating conditions 4 2 Cleaning Switch off device before cleaning and unplug the battery charging cable The device is not watertight Make sure th...

Page 22: ...yourself Please contact our sales partner where you have bought the product if you are unable to fix a malfunction by using these instructions Manufacturer s address SFC Smart Fuel Cell AG Eugen S ng...

Page 23: ...Let stand at room temperature for approx 24 hours before operating Interruption Surroundings too warm Error 32 41 Ambient temperature is too high The unit starts again as soon as it has cooled down Pl...

Page 24: ...mperature is below 45 C Please check battery voltage Error 50 51 52 53 Error 50 Battery voltage is too low sense line Error 51 Battery voltage is too high sense line Error 52 Battery voltage is too lo...

Page 25: ...d on the remote control If problem recurs please contact the SFC partner where you have bought the product Cause Solution Remote control has no or wrong connection Check remote control connection No b...

Page 26: ...d Unplug the charge line Always keep the device s service fluid nozzle clean Use a clean pair of scissors to cut off the tip of the cap The service fluid bottle is for one time use only Remove the exh...

Page 27: ...peratures in excess of 45 C and direct sunlight 45 C 20 C Make sure when choosing an installation space that the temperature ranges between 20 C and 45 C The unit requires air from the outside and gen...

Page 28: ...of water and particles A forced ventilation of the installation space is required to prevent heat accumulation This can be done with additional openings or an additional temperature controlled ventil...

Page 29: ...n Use proper screws and dowels if necessary so that the mounting plate cannot shake loose in case of an accident 2 Place the unit onto the mounting plate It is possible to mount the unit in 2 possible...

Page 30: ...forced ventilation within the installation space Sink the screws for the off heat flange into the holes provided Use the bow to conduct warm air to the side If you do not need the off heat bow you ca...

Page 31: ...Avoid inhaling exhaust directly or for long periods of time It is possible to collect the generated water in a separate water cartridge But make sure that there is a hose that allows the gasses includ...

Page 32: ...occur in the hose Make sure that the hose is neither clogged nor blocked The exhaust hose may not be longer than 50 cm in order to prevent freezing in winter The hose may be up to 150 cm long for summ...

Page 33: ...rtridge connecting hose is neither crushed nor kinked ELECTRICAL CONNECTION Do not place fuel cartridges or reserve cartridges in front of the air intake or outlet Do not place objects such as reserve...

Page 34: ...he wire harness included to connect the unit The circuit connecting the battery must contain a fuse Check the polarity see illustration before connecting the unit Both sensor and power lines must alwa...

Page 35: ...y and the battery supplies the power for the application The EFOY Pro can only be used to charge lead batteries which conform to the technical specification see chapter 2 3 The EFOY Pro can charge 12...

Page 36: ...l cartridge EFOY Pro Series Battery Load 1 2 3 4 5 6 7 EFOY Pro Series connecting line to fuel cell extension sense line optional battery fuse 2 A battery extension power line optional battery fuse in...

Page 37: ...tery together A widely used combination is together with solar cells In this case it is recommended to adjust the charging parameter of the EFOY Pro so that it only switches on if solar alone can not...

Page 38: ...es for drilling and sawing when flush or surface mounting 2 Use a drill to start the opening and then cut out the rest of the opening with a keyhole or compass saw Connect the remote control with the...

Page 39: ...e DL data line included Then insert the plug into the left socket on the unit marked Remote Control If the DL 1 data line is not long enough you can replace it with a commercially available network li...

Page 40: ...xD Transmit Pin 4 Ground Pin 5 Battery voltage Pin 6 Input fuel cartridge sensor FS1 Pin 7 Input Remote on contact CC1 Pin 8 Master slave parallel operation control CC1 7 2 Computer Interface Adapter...

Page 41: ...rvise the fuel cartridge level The EFOY Pro will go in an error as soon as the fuel cartridge is empty The optional fuel cartridge sensor FS1 monitors the level of the fuel cartridge and indicates if...

Page 42: ...ce and provides two sockets to connect the interface adapter IA1 and the fuel cartridge sensor FS1 together Parallel operation It is possible to parallel up to 5 EFOY Pro s to provide a higher power o...

Page 43: ...ssing auto and simultaneously This will deactivate the function and the unit cannot be started by a remote signal If you have locked the software a padlock will appear in the first line of the display...

Page 44: ...M modem GSM 2 151 906 019 EFOY ProCube 153 002 001 Spare parts Mounting plate EFOY Pro 151 908 012 Fuel cartridge holder with belt FH1 150 905 002 Belt for fuel cartridge holder 150 905 007 Remote con...

Page 45: ...EFOY Pro set incl flange bow tube face plate and screws 151 903 021 Off heat flange EFOY Pro 151 903 020 Off heat bow 151 903 014 External face plate heat duct 151 903 013 Off heat tube 151 904 001 S...

Page 46: ...9 Output characteristic 46 9 Output cha ract eristic U I and U P characteristic as per CE test...

Page 47: ...t a Shee t M etha nol We deliver methanol in the form of secure and certified fuel cartridges that protect you in normal operation from direct contact with methanol In case of accident or nausea immed...

Page 48: ...h inhalation in contact with skin and if swallowed 3 Composition information on ingredients Chemical characterization CAS No Description 67 56 1 methanol Identification number s EINECS Number 200 659...

Page 49: ...s in case of seepage into water course or sewage system Measures for cleaning collecting Ensure adequate ventilation Absorb with liquid binding material sand diatomite acid binders universal binders s...

Page 50: ...ance the preparation Due to missing tests no recommendation to the glove material can be given for the product the preparation the chemical mixture Selection of the glove material on consideration of...

Page 51: ...own 12 Ecological information General notes Water hazard class 1 German Regulation Assessment by list slightly hazardous for water Do not allow undiluted product or large quantities of it to reach gro...

Page 52: ...hazard designation of product T Toxic F Highly flammable Risk phrases 11 Highly flammable 23 24 25 Toxic by inhalation in contact with skin and if swallowed 39 23 24 25 Toxic danger of very serious ir...

Page 53: ......

Page 54: ...www efoy com EFOY is a registered trademark of SFC Smart Fuel Cell AG...

Reviews: