3. Operation
16
1
2
3
Place a new sealed original-equipment EFOY fuel
cartridge in the system (1).
Make sure the cartridge is fixed properly for
mobile applications (2).
Only remove the childproof cap when the new fuel
cartridge has been placed into the fuel-cartridge
holder (3).
Screw the connector onto the new fuel cartridge.
Press reset on the control panel to extinguish the
yellow warning light and the maintenance message.
Notes:
For mobile applications the fuel cartridge needs to
be properly fixed with a fuel cartridge holder.
The optional M28 adaptor is required to connect the
M28 cartridge to the EFOY Pro.
Connect the M28 fuel cartridge
Connect the EFOY Pro fuel cartridge connector (1)
with the M28 adaptor (2).
Screw the M28 adaptor (2) onto the M28 fuel
cartridge (3).