5. Troubleshooting
24
Message
Solution
Please check fuel cartridge
connector
(Error 72)
Check fuel cartridge connection and screw cartridge on
tightly.
Check cartridge hose for kinks. Check hose and
connection for dirt.
Please refill service fluid
(Error 30, 31)
Add service fluid (see Chapter 5.4).
Check that exhaust can escape and that ambient
temperature is below 45° C.
Please check battery voltage
(Error 50, 51, 52, 53)
Error 50: Battery voltage is too low (sense line)
Error 51: Battery voltage is too high (sense line)
Error 52: Battery voltage is too low (power line)
Error 53: Battery voltage is too high (power line)
Check connections.
Check whether the battery is the proper type.
Check battery voltage. If too low, use an external battery
charger to recharge.
Check other charging devices such as generators or
regulators for defects.
Automatic restart
Unit is restarting automatically - please wait.