7. Data Interface and
Accessories
42
7.5
Cluster Controller CC1
1 cluster controller
2 interface adapter
3 computer connection
4 to fuel cartridge sensor
The cluster controller CC1 provides 3 functions:
Interface splitter (provide 2 sockets)
Parallel operation of up to 5 EFOY Pro’s
Remote control of one EFOY Pro (remote-on pin)
Interface splitter
The cluster controller splits the data interface and
provides two sockets to connect the interface adapter
IA1 and the fuel cartridge sensor FS1 together.
Parallel operation
It is possible to parallel up to 5 EFOY Pro’s to provide a
higher power output. The cluster controller C1 is used
to synchronize the units so that they switch on and off
together and act like one bigger fuel cell.
Units running in parallel must all be in the same
operating mode.
For a detailed description please see the cluster
controller user manual.
Automatic
P
Charging mode
A “P” for “Parallel” will appear in the first line when
the unit is operating in parallel.