GOOD 10 C- GOOD 12 C
Use and maintenance manual
Page 56
Rev.0 01/03/2019
EN
N.B.: It is recommended to use an external thermostat with OFF-SET of at least 3° if wanting to use COMFORT CLIMA
(Climate).
Setting the pellet-air mix
Setting the pellet-air mix makes it possible to adjust smoke extraction and
the quantity of loaded pellet in a simple manner. This makes it possible
to adjust combustion according to stove draught and pellet hardness. To
turn on adjustment press the P6 and P7 keys simultaneously, the following
strings will appear on the display:
Using the P6 and P7 keys modifies the draught value, using the P5
and P4 keys it is possible to dose the amount of pellet used (the value
indicated during modification only shows a percentage value that acts on
the default parameters set in the electronic board).
NB: the number indicated during parameter modification only refers to a percentage valve that acts on the default
parameters set in the electronic board (exclusively during the work phase). These values must be changed in case of
improper combustion due to, in many cases, purchasing a pellet that is different from that used during stove initial testing.
! IMPORTANT
THIS FUNCTION IS ONLY EFFECTIVE IS DURING STOVE TESTING THE PROPER
ADJUSTMENTS HAVE BEEN MADE.
Automatically loading the auger
In order to automatically load the auger (when the stove is new the loading auger is empty), complete these operations:
1. Cut and then restore power to the thermo-stove using the main switch located on the back.
2. The display will show FINAL CLEANING and then OFF
3. Keep the P4 button pressed for 2 seconds the wording MENU SET OROLOGIO (Set clock menu) appears
4. Press the P4 key 4 times: the screen will show MENU STATO STUFA (Stove state menu)
PRESS THE P1 KEY TO ACTIVATE THE AUGER
Repeat the operation multiple times until you see pellet fall in the
brazier.
It is only possible to complete this operation if the stove is in
PULIZIA FINALE (Final cleaning) or SPENTO (OFF) state!!!
THE AUGER IS STOPPED
AUGER ACTIVATED
! IMPORTANT
AFTER LOADING THE AUGER, IT IS RECOMMENDED TO EMPTY THE BRAZIER INTO THE TANK
BEFORE START-UP.
9.7. Canalisation management
The air flow in the canalisation is adjusted using the P5 button. Press the key for a few seconds and the following screen will appear:
CANALISATION SPEED. The speeds range from 1 to 5 and A Use the P5 and P4 keys to adjust the speed of the motor used to blow
into the canalisation.
9.7.1 Canalisation fan
By keeping the P6 key pressed, it regulates canalisation fan.
CANALISATION FAN
0
PELLET
0
TIRAGGIO
2
PELLET
- 3
TIRAGGIO
2000
150°
COCLEA 0
STATO 0
2000
150°
COCLEA 1
STATO 0
1
VELOCITA
CANALIZ-
|
|
|
|
|
|
Summary of Contents for Good 10 C
Page 2: ......
Page 20: ...Manuale uso e manutenzione GOOD 10 C GOOD 12 C Pag 20 Rev 0 01 03 2019 ITA 4 x4 5 ...
Page 49: ...GOOD 10 C GOOD 12 C Use and maintenance manual Page 49 Rev 0 01 03 2019 EN 4 x4 5 ...
Page 77: ...Manuel d utilisation et d entretien GOOD 10 C GOOD 12 C Page 77 Rev 0 01 03 2019 FR 4 x4 5 ...
Page 105: ...Manual de uso y mantenimiento GOOD 10 C GOOD 12 C Pág 105 Rev 0 01 03 2019 ES 4 x4 5 ...
Page 133: ...Manual de uso e manutenção GOOD 10 C GOOD 12 C Pag 133 Rev 0 01 03 2019 PT 4 x4 5 ...
Page 152: ...DATE WORK PERFORMED MAINTENANCE ...
Page 153: ...DATE WORK PERFORMED MAINTENANCE ...
Page 154: ......
Page 155: ......