30
Service Guide: Fiery Central Solo for KM
Service Procedures
3
Carefully push the clip away from the battery until the socket ejects the battery.
Figure 12:
Motherboard battery
4
Slide the battery out of its socket.
5
To insert a new battery, slide it into the socket so that the positive (+) side of the battery faces up.
6
Press the battery down into the socket until it snaps into place.
Make sure that the battery is securely installed in the socket.
7
Reassemble the FC Solo and verify functionality (see
).
8
Configure the system date and time (see
To configure the system date and time
1
On a client computer that is connected to the same network as the FC Solo, open a Web browser window.
2
In the URL field of the browser, type the IP address or DNS name of the FC Solo, and press Enter.
The IP address is listed under the Network Setup section of the FC Solo Configuration page.
3
On the WebTools home page, click the Configure tab.
4
Click Launch Configure, type the Administrator password for the FC Solo, and then click OK.
The default Administrator password is
Fiery.1
. However, the network administrator may have configured a new
password for the FC Solo.
5
Expand the Server item in the left pane, and click Regional Settings.
6
Click the Set button next to Date and Time.
7
In the dialog box that appears, specify the current date and time, and click OK.
8
Click Reboot.
1
Clip
2
Battery
3
Socket
1
2
3