Betriebsanleitung für Druckluftenthäuter PLE-10
17
GB
Fig. 8
4. Now press the blade guard down against the
screw end stops with one finger and tighten the
clamping screw to 3 Nm (Fig. 9). Use the torque
wrench supplied for that purpose!
Fig. 9
Changing the blade
Warning!
Before any ma nipulation of the
machine, the c ompressed air s upply
must be closed or decoupled!
Warning!
Never put y our ha nd ne ar the s harp
side of the blade. Otherwise you may
cut yourself badly!
Important!
Never switch the machine on without
the b lade guard in place o r with a
loose blade guard! This would cause
destruction o f th e b lade an d a
possible ris k of injury
through
broken blade fragments.
Changing the blade:
1. Release the clamping screw and slotted screw
and remove them with the support plate (Fig. 10).
Fig. 10
2. Eject the guide pins with a hexagonal wrench 3
mm or similar (fig. 11).
Fig.
11
3. Pull the blade guard off forwards or in the upwards
direction (fig. 12).
Fig. 12