1.4.3 Choosing the Installation Location
The ES-5208P can be installed in either of the following ways as required:
On the work platform
on a rack
1.4.3.1 Installing the ES-5208P on the Work Platform
The common way is to install the ES-5208P on a clean work platform. Pay attention to the following precautions:
Ensure that the work platform is flat and stable.
Ensure good ventilation of air ports on both sides of the device.
Do not put heavy objects on the device.
1.4.3.2 Installing the ES-5208P on a Rack
Before installing the ES-5208P on a rack, you need to install the provided L- Clamps on both sides of the ES-5208P
1.5 Electrical Setup
1.5.1 Setting Up the Power Interface
After placing the ES-5208P to a flat and stable surface, insert the supplied power cable to the power socket, and
connect the other end of the cable to the power interface of ES-5208P.
1.5.2 Setting Up the Ethernet Interfaces
The ES-5208P provides twenty-four auto-MDI/MDI-X Ethernet service interfaces of standard RJ45 connectors. You
can use either the crossover or straight through cable to connect an interface.
Note:
To ensure good quality of the data signal, the length of the network cable connected to the Ethernet
interface should be shorter than 100m.
1.6 Device Startup
1.6.1 Check Before Power-On
Before powering on the device, check the following:
Whether the voltage of the power supply is consistent with the power requirement of the device.
Whether the power cable is correctly connected.
Whether the device is correctly connected to the ground on the rear side.