- 25
-
ENGLISH
INSTALLATION
FIRE DAMPERS
(with installation of the damper on
the smoke channel)
The damper must be easy to manoeuvre and its position must
be easily visible.
The damper must remain fi xed in the preset position and must
not be able to close automatically.
The smoke damper must NOT fully close the fl ue pipe but must
always ensure a minimum opening equal to 3% of the cross-
section of the pipe, and in any case at least equal to 20 cm².
The stove is already equipped with its own combustion
adjustment control that would make use of the damper redun-
dant, with the exclusion of cases in which the draw from the
chimney is greater than 30 Pa (0.3 mbar).
However the damper may close the smoke duct whilst the fi re-
box is being cleaned and when the stove is not in use, preven-
ting the return of air from the chimney into the room.
THERMOSTATIC VALVE (optional)
Equipment used to adjust combustion automatically using a
temperature probe.
This makes it possible to only consume the amount of wood
needed to reach the desired level of thermal comfort, preven-
ting unnecessary wastage.
To purchase, contact your local dealer.