![EDG Fv Plus Sinter Instruction Manual Download Page 5](http://html.mh-extra.com/html/edg/fv-plus-sinter/fv-plus-sinter_instruction-manual_2359337005.webp)
Manual
done on the burn platform.
• Management by microprocessing.
• Easy operation and visualization of the burn parameters. ·
• Nonvolatile memory keeps the last program in use.
• Ambient working temperature at 1,100°C for ceramic and 1,180°C
for sintering/infiltration.
• Maximum temperature limiter at 1,200°C
• Linear heating speed from 0.1 to 70.0°C/min.
• Thyristored power control
• Burn time for ceramic from 0 to 30 minutes.
• Burn time for sintering/infiltration from 0 to 9 hours and 59 minutes.v Decreasing
time visualization.
• Vacuum time from 0 to 30 minutes with decreasing time visualization.
• Automatic or manual (which can be activated ant any stage of the process)
vacuum operation
• Safety systems protect the equipment from operation mistakes or defects.
• Flashing and beeping signs of all process steps.
• To avoid ambience heating and save energy, an alarm will sound after 10 minutes
if the equipment is not being operated and a “Prot” message will also be displayed
warning that the muffle should be partially and manually closed.
• Quick cooling.
• Operation time totalizer.
• Low cost muffle replacing system.
• Electronic system forced ventilation keeps the components safe.
4
Installing
The numbers in parentheses refer to the pictures that follow.
Your Fv-Plus-Sinter should be far from curtains and inflammable material. A
furnace is a heat generator which needs to be dissipated; otherwise its
components will be overheated. Therefore, place the equipment at a ventilated
area which allows free air circulation. It is advisable to leave a 15cm clearance
between the furnace and anything that can impair the ventilation. Place the furnace
far from taps or basins which can sprinkle water over the equipment.
4
Summary of Contents for Fv Plus Sinter
Page 1: ...Manual CAPA ...