Helios 20, 50 or 100 W, User Manual – 01/2011
Page 65
CUR?
Consumed power supply voltage of the RF block.
>CUR?
3.5A
DATE?
Displays the date.
>DATE?
14/12/2001
DATE=date
Sets the date:
date=DD/MM/YYYY (DD: day / MM: month /YYYY year 4 characters)
>DATE=22/03/2002
22/03/2002
DISP?
Displays parameters on the bottom line of the displayer (the
N/A value has been added).
>DISP?
PWR
DISP=disp
Sets the display of the bottom line of the display in DISTANT
mode.
If disp=PWR
Displays the forward power bargraph.
If disp=DEV
Displays bargraph deviation.
If disp=NAME
Displays default name of RDS name if available.
If disp=N/P
Displays alternately default or RDS name (if present) and the
bargraph power.
If disp=N/D
Displays alternately default or RDS name (if present) and the
bargraph deviation.
>DISP=N/P
N/P
EVENT?
Displays information about at least one fault during the last
change to LOCAL mode.
>EVENT?
YES
EXTALARM?
Indicate a working default that is external to the device.
>EXTALARM?
OFF
F?
Displays transmission frequency of the exciter.
>F?
98.75MHz
F=
freq
Sets transmission frequency between 87.50 and 108.00 MHz.
>F=106.50
106.50MHz