Head Office : Parc d’activites Kennedy - 20, avenue Neil Armstrong – F-33700 Bordeaux-Merignac (France)
Tel +33 (0)5 57 928 928 – Fax +33 (0)5 57 928 929 –
www.ecreso.com – [email protected]
Helios 20, 50 or 100 W, User Manual – 01/2011
Page 67
INTMAXVSWR=threshold
Enables to edit the threshold of VSWR internal alarm
of the Goliathplus amplifier.
>INTMAXVSWR=1.8
1.8
IRANGE?
Displays the level of the input range of the coder or MPX input
if no coder available.
>IRANGE?
12dB
LINK?
Displays condition of safety chain.
If OPEN
Chain
OK.
If CLOSE
Chain closed; safety option activated, HF power is cut.
Warning: this command is available on HELIOS only if CAN
card is available.
>LINK?
OPEN
LIST
Displays the complete available information in alphabetic
order. There are different kinds of information that can be
grouped in two different categories:
- Information displaying other information or a non editable
value ( : )
- Information that can be edited ( = )
>LIST
3DB=0
AUTO3DB:ON
ALARM3DB:OFF
ALARMTEMP:OFF
etc...
LOG
This command displays the 200 events of the log. Next events
are stored: START, STOP, SOFT_RESET, LOCAL, DISTANT,
STAND-BY, SET_RF, SET_NAME, SET_FREQ,
SET_PASSWORD, SET_POWER, SET_3DB,
SET_MAXVSWR, ALARM_UNLOCK, ALARM_TEMP,
ALARM_3DB, ALARM_VSWR, CLIM_OUT, CLIM_OK,
ALARM_END, LINK_OPEN, LINK_CLOSE, PLAY, PAUSE,
LOAD_CONFIG.
>LOG
Events listing
N G L I S
Event
1:
12:54
14/12/2001
ALARM_END
Event
2:
12:48
14/12/2001
ALARM_3DB
Event
3:
12:48
14/12/2001
ALARM_VSWR
Event
4:
11:35
13/12/2001
DISTANT
Event
5:
11:34
13/12/2001
SET_FREQ
Event
6:
11:33
13/12/2001
LOCAL
-
-
-
Event 198:
G L I S
Event 199:
Event 200: