www.ecreso.com – [email protected]
Helios 20, 50 or 100 W, User Manual – 01/2011
Page 64
3DB=Threshold
Set the threshold to activate the RF alarm (3dB)
If threshold=xxxx
Fix the alarm threshold and set the AUTO3DB parameter in OFF.
If threshold=OFF
Stop power alarm and sets OFF the AUTO3DB on OFF.
If threshold=AUTO
The AUTO3DB parameter is set ON. In this case, the threshold
calculation is done in each output of LOCAL mode, splitting in
two the transmitted HF power.
>3DB=100
100
-> alarm threshold fixed at 100W.
AUTO3DB?
Displays the calculation mode of the automatic or manual
power alarm thresholds
>AUTO3DB?
ON
ALARM3DB?
Displays information about a 3dB alarm.
>ALARM3DB?
ON
ALARMTEMP?
Displays an overheating alarm.
>ALARMTEMP?
OFF
ALARMVSWR?
Displays information about a VSWR alarm.
>ALARMVSWR OFF
AUDIO?
RDS option and FM transmitter available.
If NONE
No
options.
If RDS
RDS
option.
If MON
FM
transmitter
option.
If RDS/MON
RDS and FM transmitter options.
>AUDIO?
RDS/MON
CLREVENT?
Erases the fault appeared during the last change to LOCAL
mode (see EVENT command).
>CLREVENT?
OK
CODER?
Displays information on the coder connected.
If ANALOG
Analog
coder.
If NONE
No
coder.
If
coder. (mono or stereo).
If DIGITAL
Digital coder (mono or stereo).
If XXX
Other
options.
>CODER?
ANALOG