11 - GENERAL MAINTENANCE AND CLEANING
11-3 Condensate Collector
•
Loosen upper hose clamp securing condensate
collector to flue pipe using 3/8" socket with 6"
extension.
• Remove ¼-20 hex flange nuts securing condensate
collector to heat exchanger using 7/16" deep well
socket. See figure 11-3.
•
Remove condensate collector assembly from heat
exchanger and flue pipe.
•
Flush collector and condensate trap with water.
•
Follow Burner Inspection Kit instructions to reassemble
boiler and resume operation.