9 - START UP PROCEDURE
9.1 Central Heating System Connections - HEAT ONLY
GMHB125 HEATING ONLY
WITH
OPTIONAL INDIRECT DHW
CONNECTION
GMHB160 HEATING ONLY
A
A
B
D
E
B
C
D
E
GMCB200 COMBI
LEGEND
GMCB150
GMCB200
A
Heating return connection
1" NPT
B
Cold DHW inlet tap / system filling
connection for Combi
3/4 NPT
3/4" NPT
C
Gas shutoff connection
3/4" [22.2mm]
D
DHW outlet/indirect storage tank
connection
3/4 NPT
3/4" NPT
E
Drain connection for condensate
3/4 NPT
3/4 NPT
F
Heating supply connection
1" NPT
G
5 gpm DHW flow restrictor
(Factory installed) (160C only)
na
3/4" NPT
E
F
D
C
B
A
A
B
C
D
E
F
GMCB150 COMBI
9.2 Central Heating System Connections - COMBI
LEGEND
125B
160B
A
Heating return connection
1" NPT
B
Gas shutoff connection
3/4" NPT
C
Indirect tank supply connection
3/4" NPT
na
D
Heating supply connection
1" NPT
E
Drain connection for condensate
3/4 NPT
3/4 NPT
PN 240012363 REV. A [08/31/2018]