SPLIT-TYPE ROOM AIR CONDITIONER
inStallation inStructionS – indoor unit
PRIOR TO INSTALLATION
Before installing the indoor unit, refer to the label on the product
box to make sure that the model number of the indoor unit
matches the model number of the outdoor unit.
Step 1: Select installation location
Before installing the indoor unit, you must choose an appropriate
location. The following are standards that will help you choose an
appropriate location for the unit.
Proper installation locations meet the following standards:
Good air circulation
Convenient drainage
Noise from the unit will not disturb other people
Firm and solid—the location will not vibrate
Strong enough to support the weight of the unit
A location at least one meter from all other electrical devices
(e.g., TV, radio, computer)
DO NOT install unit in the following locations:
Near any source of heat, steam, or combustible gas
Near flammable items such as curtains or clothing
Near any obstacle that might block air circulation
Near the doorway
In a location subject to direct sunlight
NOTE
About wall hole
If there is no fixed refrigerant piping:
While choosing a location, be aware that you should leave ample
room for a wall hole (see Drill wall hole for connective piping step)
for the signal cable and refrigerant piping that connect the indoor
and outdoor units.
The default position for all piping is the right side of the indoor unit
(while facing the unit).
However, the unit can accommodate piping to both the left
and right.
INDOOR UNIT INSTALLATION