EDEM
SPLIT-TYPE ROOM AIR CONDITIONER
Step 5: Connect drain hose
By default, the drain hose is attached to the left hand side of unit
(when you’re facing the back of the unit). However, it can also be
attached to the right-hand side.
To ensure proper drainage, attach the drain hose on the same
side that your refrigerant piping exits the unit.
Attach drain hose extension (purchased separately) to the end
of drain hose.
Wrap the connection point firmly with Teflon tape to ensure a
good seal and to prevent leaks.
For the portion of the drain hose that will remain indoors, wrap it
with foam pipe insulation to prevent condensation.
Remove the air filter and pour a small amount of water into the
drain pan to make sure that water flows from the unit smoothly.
PLUG THE UNUSED DRAIN HOLE
To prevent unwanted leaks you must plug the unused drain hole
with the rubber plug provided.
On drain hose placement
Make sure to arrange the drain hose according to Fig. 3.5 .
DO NOT
kink the drain hose.
DO NOT
create a water trap.
DO NOT
put the end of drain hose in water or a container that will
collect water.
1
2
3
4
5
NOTE