take note of fuSe SPecificationS
Pay attention to live Wire
Unscrew the cable clamp below the terminal block and place
it to the side.
Facing the back of the unit, remove the plastic panel on the
bottom left-hand side.
Feed the signal wire through this slot, from the back of the unit
to the front.
Facing the front of the unit, match the wire colors with the
labels on the terminal block, connect the u-lug and and firmly
screw each wire to its corresp onding terminal.
The air conditioner’s circuit board (PCB) is designed with a fuse
to provide overcurrent protection. The specifications of the
fuse are printed on the circuit board, such as: T3.15A/250VAC,
T5A/250VAC, etc.
Prepare the cable for connection:
Using wire strippers, strip the rubber jacket from both ends of
signal cable to reveal about 15cm (6in) of the wires inside.
Strip the insulation from the ends of the wires.
Using wire crimper, crimp u-type lugs on the ends of the wires.
While crimping wires, make sure you clearly distinguish the Live
(“L”) Wire from other wires.
Open front panel of the indoor unit.
Using a screwdriver, open the wire box cover on the right side of
the unit. This will reveal the terminal block.
1
2
3
4
5
6
7
a
b
c
ALL WIRING MUST PERRFORMED STRICTLY IN ACCORDANCE WITH
THE WIRING DIAGRAM LOCATED ON THE INSIDE OF THE INDOOR
UNIT´S WIRE COVER.