17
EDEM
SPLIT-TYPE ROOM AIR CONDITIONER
If refrigerant piping is already embedded in the wall, do the
following:
Hook the top of the indoor unit on the upper hook of the
mounting plate.
Use a bracket or wedge to prop up the unit, giving you enough
room to connect the refrigerant piping, signal cable, and drain
hose. Refer to Fig. 3.13 for an example.
Connect drain hose and refrigerant piping (refer to Refrigerant
Piping Connection section of this manual for instructions).
Keep pipe connection point exposed to perform the leak
test (refer to Electrical Checks and Leak Checks section of this
manual).
After the leak test, wrap the connection point with insulation
tape.
Remove the bracket or wedge that is propping up the unit.
Using even pressure, push down on the bottom half of the unit.
Keep pushing down until the unit snaps onto the hooks along
the bottom of the mounting plate.
Keep in mind that the hooks on the mounting plate are smaller
than the holes on the back of the unit. If you find that you don’t
have ample room to connect embedded pipes to the indoor
unit, the unit can be adjusted left or right by about 30-50mm
(1.25-1.95in), depending on the model. (See Fig. 3.14).
1
2
3
4
5
6
7
unit iS adJuStaBle
inStallation inStructionS – outdoor unit
Step 1: Select installation location
Before installing the outdoor unit, you must choose an
appropriate location. The following are standards that will help
you choose an appropriate location for the unit.
Proper installation locations meet the following standards:
Meets all spatial requirements shown in
Installation Space Requirements ( Fig. 4.1 )
Good air circulation and ventilation
Firm and solid—the location can support the unit and will
not vibrate
Noise from the unit will not disturb others
Protected from prolonged periods of direct sunlight or rain.
OUTDOOR UNIT INSTALLATION
DO NOT install unit in the following locations:
Near an obstacle that will block air inlets and outlets
Near a public street, crowded areas, or where noise from the unit will
disturb others
Near animals or plants that will be harmed by hot air discharge
Near any source of combustible gas
In a location that is exposed to large amounts of dust
In a location exposed to a excessive amounts of salty air