Service is required
Indication:
Icon Service is on
Cause: The combustion system malfunctioned and is not operational. This can be due to:
Code E001: Keyboard error
Code E002: IR communication error
Code E003: RF communication error
Code E004: MB communication error
Code E101: Fire error or water overtemperature
Code E105: NTC2 error
Code E106: NTC3 error
Code E107: TC2 error
Code E108: Security switch error
Code E109: Pressure switch error
Code E110: NTC1 error
Code E111: TC1 error
Code E112: Fuel overtemperature
Code E115: General error
Solution: Note the error code and contact the service personnel.
LED indicators on controller
The Fumis ALPHA controller is equipped with two LED indicators, which show the operation of the controller. The table
below describes the functions of the LED signals:
Signal
LED 2
LED 1
Function
Power supply check
Communication check
OFF
No power supply
Faulty or not programmed
Lit
Power supply OK
–
Fast blinking
(5 blinks per second)
–
Communication OK
Slow blinking
(2 blinks per second)
–
Unit not programmed with the
Fumis PC-PRO application, only
bootloader
Power supply failure
During power supply fail, the Fumis ALPHA controller remains active due to internal battery. Internal status remains as
it was before the power failure. Internal electronics runs in power saving mode consuming very low battery power
(approx. 10nA) thus allowing very long battery life (10 years min).
In case of a power supply failure the Fumis ALPHA controller operates as follows:
Duration of power
supply failure
Operation before the power
supply failure
Operation after the power supply failure
Less than 2 minutes
Fire Up phase
The controller continues normally
Burning phase
The controller checks the air/water temperature
and continues in the Burning phase, or restarts in