42
Feeder 2 settings
Feeder 2 is usually used for dosing secondary fuel or as pellets transporter from the main storage. It can also be
used for mixing different fuels (pellets and olive stones, for example) in fixed proportions (%).
For detailed description of feeder 2 operation refer to chapter
Error! Reference source not found.
on page
Error! Bookmark not defined.
.
No.
Parameter
Description
91
Feeder 2 Delay / ON Time Factor
Feeder2 dosing delay / activation time factor:
Defines the feeder 2 operation time (in seconds) if
Fuel Level
Sensor
configuration option is set and Feeder2 acts as pellets
transporter from the main fuel storage to the stove pellets
buffer.
Defines the relative dosing to the main feeder if
Pellets Level
Sensor
configuration option is not selected:
50
– feeder 2 is 50% slower than the main feeder
150
- feeder 2 is 50% faster than the main feeder
NOTE: if PAR is set to 0, feeder 2 operates constantly (except
when combustion system is turned off)
Fuel Quality
No.
Parameter
Description
92
Pellets Quality
Defines one of the three pellets fuel quality types:
1
- feeder and fan 1 operate according to the hidden
parameters 53 (FeederFactorPelletsType1) and 54
(FAN1FactorPelletsType1) settings in %.*
2
- feeder and fan 1 operate according to the hidden
parameters 55 (FeederFactorPelletsType2) and 56
(FAN1FactorPelletsType2) settings in %.*
3
- feeder and fan 1 operate according to the hidden
parameters 57 (FeederFactorPelletsType3) and 58
(FAN1FactorPelletsType3) settings in %.*
NOTE: Pellets quality (1, 2 or 3) can also be selected by end
user through user interface.
* compared to ONORM M7135 standard pellets
93
Wood Quality
Defines one of the three wood fuel quality types:
1
- fan 1 operates according to the hidden parameter 59
(FAN1WoodType1) settings in %.
2
- fan 1 operates according to the hidden parameter 60
(FAN1WoodType2) settings in %.
3
- fan 1 operates according to the hidden parameter 61
(FAN1WoodType3) settings in %.
NOTE: Wood quality (1, 2 or 3) can also be selected by end
user through user interface.
Servicing
No.
Parameter
Description
94
Time to Service
Time to service warning level (in days):
Downloaded from
www.Manualslib.com
manuals search engine