417102012_LMI02.doc
- 89 -
Rev. 9-07.08
11.3.2 Temperature measurement
Measuring principle:
Resistance measurement with NTC
Temperature display:
Digital in °C (resolution 1°C)
11.3.3 Temperature compensation
Reference temperature:
20°C
Tk set point:
ALKALINE (1.9 %/K) and ACID (1.25%/K)
Settings:
Under TEMPERATURE COMP. in PARAMETER FUNCTIONS
menu
Function range of
temperature compensation:
0°C ... 100°C
Errors in temperature
compensation:
Max. 0.2 %/K between 20 and 80°C
11.3.4 Limit values
Number:
Two, “SP1” and “SP2” can be preset under CONCENTRATION
SP1/SP2 in PARAMETER FUNCTIONS menu.
Switching hysteresis:
Approx. 0.5% of preset rated value
Switching status display:
The on-state of relays SP1 and SP2 is indicated by
▲
symbol
11.3.5 Pre-metering
Can be set up under PREMETERING TIME in the
PARAMETER FUNCTIONS
menu in
a range of 0-9999 s at intervals of 1s.
11.3.6 Pre-metering delay time
Can be set up under PREMETERING DELAY in the
PARAMETER FUNCTIONS
menu
in a range of 0-9999 s at intervals of 1s.
11.3.7 Metering time monitoring
Can be set up under DETERGENT DELAY in the
PARAMETER FUNCTIONS
menu in a
range of 10-9999 s at intervals of 1s.
11.4 Outputs
Switch outputs
1 potential free change-over contact (SP1), max. load of 8 A, 230 V AC
1 potential free change-over contact (SP2), max. load of 4 A, 230 V AC
1 potential free change-over contact for collective alarm messages, of 4 A, 230 V AC
1 potential free change-over contact for pre-metering, of 4 A, 230 V AC
Current output:
0/4 - 20 mA corresponding to 0 ... 100 % of preset measuring range.
Max. burden 400
Ω
Summary of Contents for LMI 02
Page 47: ...417102012_LMI02 doc 47 Rev 9 07 08 13 Anhang 13 1 Anwendungsbeispiele Abb 13 1 Abb 13 2...
Page 51: ...417102012_LMI02 doc 51 Rev 9 07 08 13 3 Programmier bersicht 13 3 1 AS Mode...
Page 52: ...417102012_LMI02 doc 52 Rev 9 07 08 13 3 2 CIP Mode...
Page 53: ...417102012_LMI02 doc 53 Rev 9 07 08 14 Konformit tserkl rung...
Page 93: ...417102012_LMI02 doc 93 Rev 9 07 08 13 Appendix 13 1 Application examples fig 13 1 fig 13 2...
Page 97: ...417102012_LMI02 doc 97 Rev 9 07 08 13 3 Programming overview 13 3 1 AS Mode...
Page 98: ...417102012_LMI02 doc 98 Rev 9 07 08 13 3 2 CIP Mode...
Page 99: ...417102012_LMI02 doc 99 Rev 9 07 08 14 Declaration of Conformity...
Page 139: ...417102012_LMI02 doc 139 Rev 9 07 08 13 Annexe 13 1 Exemples d application Fig 13 1 Fig 13 2...
Page 143: ...417102012_LMI02 doc 143 Rev 9 07 08 13 3 Tableau de programmation 13 3 1 AS Mode...
Page 144: ...417102012_LMI02 doc 144 Rev 9 07 08 13 3 2 CIP Mode...
Page 145: ...417102012_LMI02 doc 145 Rev 9 07 08 14 D claration de conformit...