7.3.4.4 Detergent overdosage alamr
Determining a limit value for conductivity (DET: OVERDOSAGE. CONZ.: XXX mS/cm) can
prevent an overdose of detergent in the wash tank. Exceeding the determined value
triggers the DETERGENT OVERDOSAGE alarm.
An overdose of detergent can occur if, for example, the metering pump does not stop due
to a fault.
The (DETERGENT OVERDOSAGE) alarm appears on the display and the external alarm
output is activated. Press any key to confirm the external alarm output. The alarm message
remains blinking on the display until the density drops below the limit value.
The limit value for the conductivity can be set depending upon the preset density value of
SP1 to 300 mS/cm (ex-works setting is 100 ms/cm).
NOTE
The limit value for the overdose must be at least 20 % above the preset concentration
value of SP1 (a setting below 20 % is not possible).
The detergent overdose concentration must be set as follows:
1. Activate the ALARM CONTROL SETUP menu.
2. Press the
↵
key.
3. Scroll with the NEXT key until the next menu is displayed.
4. Enter the required value with the or key.
5. Press the NEXT key to confirm.
7.3.4.5 Alarm delay time for detergent overdosage
The alarm can be prevented from triggering for short-term, insignificant drops in the
concentration level (ex-works setting is 0120 s) by setting an alarm delay time (DET.
OVERDOSAGE /DELAY.: 0120 s).
The overdose concentration of detergent must be set as follows:
1. Activate the ALARM CONTROL SETUP menu.
2. Press the
↵
key.
3. Scroll with the NEXT key until the next menu is displayed.
4. Starting with the currently blinking digit, enter the required value with the or
key.
The next digit can be selected with the
↵
key.
The time can be set to a value between 1 and 9999 sec at intervals of 1 sec.
5. Press the NEXT key to confirm.
Summary of Contents for LMI 02
Page 47: ...417102012_LMI02 doc 47 Rev 9 07 08 13 Anhang 13 1 Anwendungsbeispiele Abb 13 1 Abb 13 2...
Page 51: ...417102012_LMI02 doc 51 Rev 9 07 08 13 3 Programmier bersicht 13 3 1 AS Mode...
Page 52: ...417102012_LMI02 doc 52 Rev 9 07 08 13 3 2 CIP Mode...
Page 53: ...417102012_LMI02 doc 53 Rev 9 07 08 14 Konformit tserkl rung...
Page 93: ...417102012_LMI02 doc 93 Rev 9 07 08 13 Appendix 13 1 Application examples fig 13 1 fig 13 2...
Page 97: ...417102012_LMI02 doc 97 Rev 9 07 08 13 3 Programming overview 13 3 1 AS Mode...
Page 98: ...417102012_LMI02 doc 98 Rev 9 07 08 13 3 2 CIP Mode...
Page 99: ...417102012_LMI02 doc 99 Rev 9 07 08 14 Declaration of Conformity...
Page 139: ...417102012_LMI02 doc 139 Rev 9 07 08 13 Annexe 13 1 Exemples d application Fig 13 1 Fig 13 2...
Page 143: ...417102012_LMI02 doc 143 Rev 9 07 08 13 3 Tableau de programmation 13 3 1 AS Mode...
Page 144: ...417102012_LMI02 doc 144 Rev 9 07 08 13 3 2 CIP Mode...
Page 145: ...417102012_LMI02 doc 145 Rev 9 07 08 14 D claration de conformit...