2x4 Board Laid Flat
Warning:
The Sensitivity System Reversing Test should be performed monthly to ensure that
this important system remains in proper adjustment
Testing the Safety Reverse System
Warning:
Failure to Test Reversing System Could Result in Death or Serious Injury. Test This
System Once A Month.
To test the Opener Reversing Feature at floor level place a
solid object 5cm thick on the ground so that the center of the
door will come into contact with it. Close the door. If the close
force adjustments are correct, the door will reverse within one
and a half seconds upon contacting the object and travel to
the full open position. The door will emit short beeps
continuously for 25 seconds. If this does not occur, re-check
Limit Adjustments on pg.12 and Force/Sensitivity Adjustments
pg.13.
Note:
Any time any adjustments are made to Limits or Sensitivity, You must retest the opener for the Reversing
Feature at floor level as outlined above.
Testing the Photo eye system
Start the door down and then place an obstacle approximately
20cm high by 30cm wide in the path of the beam. The Red
Pilot Light on the Silent Guard Photo Eye System should go
off. The door should stop for 1-1/2 seconds and reverse to the
full open position. The Opener will emit long beeps
continuously for 20 seconds. If the door is moving up and the
beam is broken, the door will continue up to full open. With
the door fully open and at rest, place the obstacle in the path
of the beam once again. Activate the Wall Push Button, The
Opener will revert to and remain in the Up limit position. Hold
the Wall Push Button to close the door (door will beep while it
travels to the down limit position).
*Auto Close Timer is only available with the Photo Eye
System present.
Warning:
A damaged or malfunctioning Photo Eye System can enable a garage door to close
on people or property, causing serious injury or even death. Perform this test
monthly to ensure proper operation.
NOTE:
If the garage door travels more than 5cm in a downward path after releasing the button, the Silent Guard
Photo Eye System is malfunctioning. Check all electrical connections and alignment of the Photo Eye System.
!
!
Invisible Light
Beam Protection
Sensor Beam 10-
15cm above Floor
Sensor Beam 10-
15cm above Floor
14