Read and Follow These Important Safety Instructions 

You will see 

Warning

 and 

Caution

 statements on the following Pages.  

Read and follow these safety instructions carefully. Failure to do so could result in serious personal injury or death. 

Warning

  

means that severe injury or death may result from failure to follow  instructions 

Caution

  

means that property damage or injury may result from failure to follow instructions 





Be sure to read and follow all instructions carefully. 



To reduce the risk of electric shock, this equipment has a grounding type plug, that has a third (grounding) pin. 
This plug will only fit into a grounding type outlet. If the Plug does not fit into the outlet, contact a qualified 
electrician to install the proper outlet. Do not change the plug in any way. 



Check to make sure the garage door is properly installed and balanced. 

Garage door & parts are under 

extreme tension and under no circumstance should you attempt to adjust on your own

. Have a qualified 

garage door service person make repairs to cables, spring and other hardware before installing the opener. 



Install Entrapment Warning Label next to control button. Read the Control Adjustment Warning Label. Install 
Emergency Release Tag to the Emergency Release Cord. Mount the Emergency Release Knob 180cm from the 
floor. Use the manual release only to disengage the trolley. Do not use the Red Release Cord and Knob to pull 
door up or down. If possible, use the Emergency Release only when the door is closed. 



Do not connect opener to power source until instructed. Install door opener 210cm or more above floor. 



After installing opener, the door must reverse when it comes in contact with a 5cm high object. Check this safety 
feature often. 



REMOVE ALL ROPES CONNECTED TO THE GARAGE DOOR. 



DISENGAGE ALL EXISTING GARAGE DOOR LOCKS TO AVOID DAMAGE TO THE GARAGE DOOR. 



Fiberglass, aluminum and steel doors must be reinforced to prevent damage. Consult with manufacturer for 
recommendations. 



All installation and wiring must be done in strict compliance with local and state building and electrical codes. 
Connect the power cord to a properly grounded outlet only. Do not in any way alter or remove the grounding pin. 

Photo Eye System must be installed properly. Guardian Operators recommend Photo Eye System is installed on 
every garage door for your added protection. Opening doors must not close and Closing doors must open once 
the beam is broken.   See the test procedure page 13 and page 14. 



Locate push button within sight of garage door, away from all moving parts and out of reach of children (minimum 
150cm above floor). To reduce the risk of injury to persons, use this operator only with a sectional door. 



Never operate the opener if the system is not operating properly. 



Always disconnect electric power before making repairs or removing cover. 



Activate opener only when the door is in full view and free from obstructions. 



No one should enter or leave the garage while the door is moving. Do not allow children to play near, or operate 
the door. Keep the remote control away from children. 



After Installation is complete fasten this manual near the garage door. Perform periodic safety checks and 
recommended maintenance and adjustments. 



NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR.



Test door opener monthly. The garage door MUST reverse on contact with a 5cm high object (or a two by 4 
board laid flat) on the floor. After adjusting either the force or the limit of travel, retest the door opener. Failure to 
adjust the opener properly increases the risk of severe injury or death. 



For products having an emergency release, when possible, use the emergency release only when the door is 
closed. Use caution when using this release with the door open. Weak or broken springs are capable of 
increasing the rate of door closure and increasing the risk of severe injury or death. 



KEEP GARAGE DOORS PROPERLY BALANCED. See ownerʼ

s manual. An improperly balanced door increases 

the risk of severe injury or death. Have a qualified service person make repairs to cables, spring assemblies, and 
other hardware. 



SAVE THESE INSTRUCTIONS. 

!

Summary of Contents for Guardian DCS2

Page 1: ...nstructions and Owner s Manual READ THIS MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION Installer Permanently attach manual to the wall Model DCS2 Sectional Garage Door Opener 03 9703 1500 www ecogara...

Page 2: ...Date Description Installation maintenance service Authorized Personnel Customer s Signature...

Page 3: ...recommendations All installation and wiring must be done in strict compliance with local and state building and electrical codes Connect the power cord to a properly grounded outlet only Do not in an...

Page 4: ...Monitor Entrapment System System allows quick and easy installation of Silent Guard Photo Eye System while control circuitry monitors these devices continuously for proper operation 8 Constant Contact...

Page 5: ...y Contact a qualified garage door service person to make the necessary adjustments Door Test Before beginning installation of the operator please complete the following test to insure that your door i...

Page 6: ...Long 1 pcs 07 Clevis Pin Short 2pcs 08 Rope Knob 1 pcs 09 Rope 1 pcs 10 Washer 2 pcs 3 2 1 Components Identification and Inventory Fastener parts in screw bag Identification 4 5 6 7 8 9 3 4 5 6 7 01...

Page 7: ...r head and slide rail over drive shaft retaining lugs Fasten with 4 nuts STEP 4 Adjust the tension of belt at end rail Turn clockwise to tighten and counterclockwise to loosen NOTE improper tension wi...

Page 8: ...a centerline on door frame and cross the previous horizontal line Fasten the cross point with screws STEP 7 Mount door bracket at the position of center of top panel with screws STEP 8 Connect track...

Page 9: ...x head machine bolts not supplied STEP 11 Insert curved arm into door bracket using clevis pin short STEP 12 Connect straight arm and curved arm and adjust to the required length Fix it with hex bolts...

Page 10: ...time now to read and familiarize yourself with the instructions on the Emergency Release Label Tie a second double overhand knot in the free end adjusting the rope so that the red knob is 180cm above...

Page 11: ...18 Assembly 05 17 STEP 17 OPTIONAL Put signal wires through the hole on the up right side STEP 18 OPTIONAL Pull out the signal wires from hole of the front side 9...

Page 12: ...10 Auto Close Timer function only works when Photo Eye System is installed Please refer to instructions included with the Photo Eye System IR Jumper Photo eye DC 24V Ground Power Button Wall Box UP O...

Page 13: ...oor at open position Transmitter Push Button Unplug Plug Half speed in Program mode open close At full speed open close Inch movement Memory is empty Light on LED the bulb Light off LED the bulb Press...

Page 14: ...ld continuously Door is traveling up at half speed When door is approaching Up limit position release Up button Door stops STEP5 Press Up or Down to micro adjust inch movement to required up limit pos...

Page 15: ...Door will then travel down at full speed and stop at down limit The Opener will beep 3 times force mode is now set Press the Force button to auto learn force STEP13 Press any button on transmitter OK...

Page 16: ...pproximately 20cm high by 30cm wide in the path of the beam The Red Pilot Light on the Silent Guard Photo Eye System should go off The door should stop for 1 1 2 seconds and reverse to the full open p...

Page 17: ...sition and at such a height that it can only be actuated by an adult The caution label is prominently displayed next to the push button 5 All wiring is correct to code There is ground continuity in th...

Page 18: ...r wear of damage Caution If service is needed contact your local garage door service person 7 Do not decrease the safety reversing sensitivity mechanism to overcome a damaged or poorly operating door...

Page 19: ...se each increment Note The maximum force is at six increment When the maximum increment has been reached Up LED blinks and beeps twice The minimum force is at 0 When the minimum increment has been rea...

Page 20: ...2 Dome Cover A 3 Light Socket A 4 Energy Saving Bulb A 5 Motor A 6 Programming Board A 7 Programming Board Cover A 8 RPM Reader A 9 Transformer A 10 Chassis A 11 Power Cord A 12 Carriage Bolt Nut A 6...

Page 21: ...oor Arm B 9 Rail B 10 Trolley Plate B 11 Emergency Pull Cord w Knob B 12 Connector Connector Link B 13 Trolley B 14 Door End Bracket B 15 Door Bracket B 16 Chain B 17 E Ring B 18 Pulley Spindle B 19 R...

Page 22: ...t itself ii To any additional damage or deterioration arising from attributable to the operation of the Operator after it is known to be defective 9 Exclusions to Warranty Period i Repair or Warranty...

Page 23: ..._____ Date of installation ________________________ List of components installed drive unit control and safety devices The technical features and performances of the components listed below are docume...

Reviews: