background image

1. Never permit children to play with or operate the garage door opener either from the wall station or the remote 

controls. Keep radio transmitter locked in the car. Misuse of the push button or transmitter could result in serious 
injury or even death. 

2. Open the garage door with the remote controls only when the garage door is fully visible to you and clear of all 

obstructions. The garage door should be kept in sight until it is completely open or closed and you are certain that the 
garage door opener has shut off. 

3. Attempting to exit the garage through the garage door opening, while the door is in motion, is a very dangerous 

activity that could result in serious injury or even death. 

4. Children and pets should always be clear of the door opening while the garage door is in motion. 

5. Check the safety reverse mechanism at least once a month to make sure that it will reverse with the minimum amount 

of force. Also check to be sure that the door will reverse within 5cm of the floor. See p.14. 

6. Check the manual operation of your garage door at least every 90 days to be sure that it is operating smoothly and 

does not bind or stick. Tighten all bolts on the door and visually check all hardware including springs for wear of 
damage. 

Caution

: If service is needed contact your local garage door service person. 

7. Do not decrease the safety reversing sensitivity mechanism to overcome a damaged or poorly operating door. This 

will adversely affect the operation of the safety reverse mechanism which could result in damage to the door, 
personal injury or even death. 

Caution:

Never operate the door opener if the reversing mechanism is not functioning properly. 

8. Whenever possible, the manual disconnect should only be used when the door is fully closed. Caution: Extreme care 

must be taken whenever the disconnect cord is pulled with the door partially open. Weak or broken springs may allow 
the door to fall rapidly resulting in property damage, personal injury or death. If a broken spring is evident, contact 
your local garage door service person immediately before disconnecting the door from the opener. Never attempt 
servicing a broken spring. 

9. Always disconnect electrical power supply to the opener when performing any maintenance or service to the opener 

or garage door. Failure to do so could result in electrical shock, property damage, personal injury or death. 

10. If any damage to any mechanical or structural component of the opener is observed, discontinue use and contact 

your local garage door service person immediately. 

11. If the door auto reverses, please ensure there is no obstruction to the track or door.  

After the Installation 

16

Summary of Contents for Guardian DCS2

Page 1: ...nstructions and Owner s Manual READ THIS MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION Installer Permanently attach manual to the wall Model DCS2 Sectional Garage Door Opener 03 9703 1500 www ecogara...

Page 2: ...Date Description Installation maintenance service Authorized Personnel Customer s Signature...

Page 3: ...recommendations All installation and wiring must be done in strict compliance with local and state building and electrical codes Connect the power cord to a properly grounded outlet only Do not in an...

Page 4: ...Monitor Entrapment System System allows quick and easy installation of Silent Guard Photo Eye System while control circuitry monitors these devices continuously for proper operation 8 Constant Contact...

Page 5: ...y Contact a qualified garage door service person to make the necessary adjustments Door Test Before beginning installation of the operator please complete the following test to insure that your door i...

Page 6: ...Long 1 pcs 07 Clevis Pin Short 2pcs 08 Rope Knob 1 pcs 09 Rope 1 pcs 10 Washer 2 pcs 3 2 1 Components Identification and Inventory Fastener parts in screw bag Identification 4 5 6 7 8 9 3 4 5 6 7 01...

Page 7: ...r head and slide rail over drive shaft retaining lugs Fasten with 4 nuts STEP 4 Adjust the tension of belt at end rail Turn clockwise to tighten and counterclockwise to loosen NOTE improper tension wi...

Page 8: ...a centerline on door frame and cross the previous horizontal line Fasten the cross point with screws STEP 7 Mount door bracket at the position of center of top panel with screws STEP 8 Connect track...

Page 9: ...x head machine bolts not supplied STEP 11 Insert curved arm into door bracket using clevis pin short STEP 12 Connect straight arm and curved arm and adjust to the required length Fix it with hex bolts...

Page 10: ...time now to read and familiarize yourself with the instructions on the Emergency Release Label Tie a second double overhand knot in the free end adjusting the rope so that the red knob is 180cm above...

Page 11: ...18 Assembly 05 17 STEP 17 OPTIONAL Put signal wires through the hole on the up right side STEP 18 OPTIONAL Pull out the signal wires from hole of the front side 9...

Page 12: ...10 Auto Close Timer function only works when Photo Eye System is installed Please refer to instructions included with the Photo Eye System IR Jumper Photo eye DC 24V Ground Power Button Wall Box UP O...

Page 13: ...oor at open position Transmitter Push Button Unplug Plug Half speed in Program mode open close At full speed open close Inch movement Memory is empty Light on LED the bulb Light off LED the bulb Press...

Page 14: ...ld continuously Door is traveling up at half speed When door is approaching Up limit position release Up button Door stops STEP5 Press Up or Down to micro adjust inch movement to required up limit pos...

Page 15: ...Door will then travel down at full speed and stop at down limit The Opener will beep 3 times force mode is now set Press the Force button to auto learn force STEP13 Press any button on transmitter OK...

Page 16: ...pproximately 20cm high by 30cm wide in the path of the beam The Red Pilot Light on the Silent Guard Photo Eye System should go off The door should stop for 1 1 2 seconds and reverse to the full open p...

Page 17: ...sition and at such a height that it can only be actuated by an adult The caution label is prominently displayed next to the push button 5 All wiring is correct to code There is ground continuity in th...

Page 18: ...r wear of damage Caution If service is needed contact your local garage door service person 7 Do not decrease the safety reversing sensitivity mechanism to overcome a damaged or poorly operating door...

Page 19: ...se each increment Note The maximum force is at six increment When the maximum increment has been reached Up LED blinks and beeps twice The minimum force is at 0 When the minimum increment has been rea...

Page 20: ...2 Dome Cover A 3 Light Socket A 4 Energy Saving Bulb A 5 Motor A 6 Programming Board A 7 Programming Board Cover A 8 RPM Reader A 9 Transformer A 10 Chassis A 11 Power Cord A 12 Carriage Bolt Nut A 6...

Page 21: ...oor Arm B 9 Rail B 10 Trolley Plate B 11 Emergency Pull Cord w Knob B 12 Connector Connector Link B 13 Trolley B 14 Door End Bracket B 15 Door Bracket B 16 Chain B 17 E Ring B 18 Pulley Spindle B 19 R...

Page 22: ...t itself ii To any additional damage or deterioration arising from attributable to the operation of the Operator after it is known to be defective 9 Exclusions to Warranty Period i Repair or Warranty...

Page 23: ..._____ Date of installation ________________________ List of components installed drive unit control and safety devices The technical features and performances of the components listed below are docume...

Reviews: