4.
Simbols
e-system
On/Off Status.
Alarm.
e-system
surplus control mode active.
e-system
consumption control mode active.
Active heat pump compressor regulation.
Active non-critical load.
Generated power.
Consumption/Injection from/to the public
grid.
5.
Alarms and troubleshooting
5.1.
Active alarms
An alarm icon
on the main display screen indicates a malfunction of the
e-system
. In this case, the red alarm LED on the display
remains on. It can also happen that the display does not show any alarm signal, but the LED flashes, which means that there has
been an alarm that has already been solved. In both cases, you can access the alarm log to check the status of the machine.
Alarm message
Diagnosis
Steps
Loss of com. with the heat
pump.
Communication with the heat
pump has been lost.
-Check that the inverter is on and powered.
-Check the connection of the heat pump with the controller in the panel. Make
sure the wires are not damaged.
-Check the pLAN port settings in the installer menu.
Loss of communication with
the inverter.
Communication with the inverter
has been lost.
-Check that the inverter is on and powered.
-Check the connection of the inverter with the controller in the panel. Make
sure the wires are not damaged.
Inverter failure.
There has been a problem with the
solar inverter.
-Access the alarm log to view the failure code.
Table 5.1.
List of alarms on the control panel
In the event that your
e-system
registers a communication alarm, and once you have made sure that the wires connection is correct,
on many occasions the solution could be to reset the default values of the equipment. If the problem persists, please contact the
ECOFOREST technical service.