ECOFOREST ecoSMART e-system User Manual Download Page 14

User manual 

ecoSMART e-system

 

 

12 

 

EN

 

 

 

Grid balance 

Displays information regarding the actual instantaneous balance read at the border, the 
set for surplus regulation and the configured consumption limit. 

 

 

 

Power meters 

Allows to visualize in real time the power flow exchanged in each point of the installation. 

 

 

 

Maximeters 

Allows  to  visualize  for  every  month  the  values  of  the  maximum  power  in  the  different 
points of the installation: maximum total power consumed by the installation, maximum 
power  generated  in  the  source  and  maximum  power  consumed  from  the  electrical 
network. 

 

 

 

Grid meters 

Allows to visualize for every month the values of consumed and injected energy to the grid. 

 

 

 

Installation meters 

Allows to visualize for each month the values of electrical energy generated by the panels 
with their useful use coefficient (energy generated used in the installation, that is to say, 
that it is not dumped to the grid) and the total energy consumed by the installation with 
its solar coverage ratio (self-consumed generated energy) for the same.

 

 

 

Heat pump meters 

Allows to visualize the electrical energy consumed and thermal energy produced by the 
heat pump for each month. It also shows the ratio of energy consumed by the pump that 
has been covered by solar generation and the ratio of thermal energy produced in surplus 
regulation. 

 

 

 

Version 

Includes information about 

e-system

 software version and the controller software. 

 

3.14.

 

ALARMS Menu 

Press 

 for quick access to the alarms menú from the main screen. 

/7

Grid balance

Real:                   

7kW

Surplus:

kW

onsum limit:

-44kW

Power meters

onsumption:

38W

Generation:

457W

Grid:

95W

Batteries:

W

-44kW

Batt level:

%

Maximeters

SEPTEMBER

38W

onsumption:

5kW

95W

Generation:

49kW

%

Grid:

kW

Grid meters

SEPTEMBER

onsumption:

83kWh

Injection:

3kWh

kW

Installation meters

SEPTEMBER

Generation:

87kWh

Useful:

99%

3kWh

onsumption:

873kWh

Solar:

7%

Heat pump meters

SEPTEMBER

onsumption:

37kWh

Production:

985kWh

873kWh

Solar:

7%

Surplus:

38%

Version

Ver: B5_EM_V3B_E 

Date:

//9

Bios: 4

5//4

Boot: 45

4//3

Summary of Contents for ecoSMART e-system

Page 1: ...10 2020 VERSI N SOFTWARE v07b05 ecoSMART e system MODEL SERVICE CONTACT USER MANUAL EN...

Page 2: ......

Page 3: ...salida activas en el controlador 7 3 6 List of installer menu 9 3 7 Parameters adjustment 10 3 1 ON OFF Menu 10 3 2 SCHEDULE Menu 10 3 3 SURPLUS CONFIGURATION Menu 11 3 4 CONSUMPTION CONTROL Menu 11...

Page 4: ...afety considerations The detailed instructions in this section cover important aspects for your safety as such they must be strictly complied with DANGER All the installation and maintenance work must...

Page 5: ...ception of small localised fires only the fire brigade is equipped and authorised to intervene in fire extinguishing manoeuvres If the fire has spread you must leave the site and get to safety immedia...

Page 6: ...time ensuring that the comfort of the home configured in the heat pump is not compromised In this way we are able to considerably reduce dependence on the electricity grid to supply the pump which mea...

Page 7: ...plied at 230V configuring a series of parameters associated with the energy balance between the electrical grid and the consumption of the installation Battery electrical storage The ecoSMART e system...

Page 8: ...parameters Figure 3 1 Control panel The general functions of each of the buttons and operation is indicated below The ALARMS menu can be accessed directly from anywhere in the application The list of...

Page 9: ...he controller still run but the alarm warns us of abnormal behavior and registers it 3 4 Operating modes The operating modes active in the ecoSMART e system are reflected in the main screen and give a...

Page 10: ...al ecoSMART e system 8 EN REGULATION signal An output for speed control of the heat pump compressor has been activated NON CRITICAL LOAD ACTIVE signal Relay output to non critical load enabled up to f...

Page 11: ...3 Browsing through the list of user menus XXXXXX XXXXXX XXXXXX 9 Fri 4 5 kW 3 8 kW 4 5 User menu 7 On Off Date and hour Surplus control 4 5 User menu 7 On Off Date and hour Surplus control 4 5 User m...

Page 12: ...nd return to position 1 7 With the cursor in position 1 again press buttons to go to the previous or next screen or to return to the list of user menus Figure 3 4 Adjusting comfort parameters 3 8 ON O...

Page 13: ...independent non critical loads through the output relays of the manager 3 13 INFORMATION Menu Press for quick access to the information men from the main screen Daily saving time Enable Transition ti...

Page 14: ...to the grid and the total energy consumed by the installation with its solar coverage ratio self consumed generated energy for the same Heat pump meters Allows to visualize the electrical energy consu...

Page 15: ...ms This screen displays the active alarms The button illuminates Reset alarms It allows us to reset alarms once solved User menu 7 7 Non critical loads Information Alarms 8 8 Alarms Lost comm with the...

Page 16: ...ith the heat pump Communication with the heat pump has been lost Check that the inverter is on and powered Check the connection of the heat pump with the controller in the panel Make sure the wires ar...

Page 17: ...8 V Battery voltage range 40 60 V Charge max current 50 A Recharge curve 3 stage adapter with maintenance Over current temperature protection Yes Interfaz de comunicaci n Can RS232 Electronic AC power...

Page 18: ...iciency 97 6 Euro efficiency 97 MPPT efficiency 99 9 Safety and protections Overload protection Yes Overtemperature protection Yes Overvoltage undervoltage protection Yes Overload protection category...

Page 19: ...nonconformity For the warranty to be effective the purchaser must present a legal document that supports the date of purchase duly stamped and signed from the establishment that made the sale Disclai...

Page 20: ...NOTES...

Page 21: ......

Page 22: ......

Page 23: ...ontes 25 36350 Nigr n Pontevedra Spain Tel 34 986 262 184 34 986 417 700 Fax 34 986 262 186 e mail Info ecoforest es http www ecoforest es The manufacturer reserves the right to make any necessary cha...

Reviews: