Battery module 

Type 

LiFePO4 

Rated voltage 

48 

Rated capacity 

2.400 

Wh 

Usable capacity 

2.200 

Wh 

DOD 

90 

Charge voltage 

52,5-54 

Discharge voltage 

45-54 

Recommended charge/discharge current 

25 

Max. charge/discharge current 

50 

Charge/discharge peak current (15 s) 

100 

Work temperature 

Charge 

0-50 

 

Discharge 

-10-50 

 

Dimensions WxHxD 

440x88,5x410 

mm 

Weight 

24 

Kg 

Desing life (25

>10  

year 

Life cycle (25

, 90% DOD) 

>4.500 

cycles 

Communication interfaces 

RS232, RS485, CAN 

Certifications 

TüV/CE/UN38.3 

Efficiency 

Max. Invertir efficiency 

97,6 

Euro efficiency 

97 

MPPT efficiency 

99,9 

Safety and protections 

Overload protection 

Yes 

Overtemperature protection 

Yes 

Overvoltage/undervoltage protection 

Yes 

Overload protection category 

III (grid side) II (PV side) 

DC isolation impedance 

Yes 

DC injection monitoring 

Yes 

Anti-islanding protection 

Yes 

PV overcurrent protection 

Fuses 12A DC (positive and negative pole) 

Battery overcurrent protection 

DC Fuse 50A 

AC line protection 

External installation 

EPS line protection 

External installation 

Others 

Inverter topology 

Transforless 

Protection class 

IP20 (indoor use) 

Operating temperature range 

-20-60 

 

Sound emission 

<40 

dB 

Standby consumption 

<42 

Dimensions WxHxD 

720x1058x710 

mm 

Weight (only with one module) 

118 

Kg 

EMC Standard 

IEC61000-6-1/2/3/4 

 

 

Summary of Contents for ecoSMART e-system

Page 1: ...10 2020 VERSI N SOFTWARE v07b05 ecoSMART e system MODEL SERVICE CONTACT USER MANUAL EN...

Page 2: ......

Page 3: ...salida activas en el controlador 7 3 6 List of installer menu 9 3 7 Parameters adjustment 10 3 1 ON OFF Menu 10 3 2 SCHEDULE Menu 10 3 3 SURPLUS CONFIGURATION Menu 11 3 4 CONSUMPTION CONTROL Menu 11...

Page 4: ...afety considerations The detailed instructions in this section cover important aspects for your safety as such they must be strictly complied with DANGER All the installation and maintenance work must...

Page 5: ...ception of small localised fires only the fire brigade is equipped and authorised to intervene in fire extinguishing manoeuvres If the fire has spread you must leave the site and get to safety immedia...

Page 6: ...time ensuring that the comfort of the home configured in the heat pump is not compromised In this way we are able to considerably reduce dependence on the electricity grid to supply the pump which mea...

Page 7: ...plied at 230V configuring a series of parameters associated with the energy balance between the electrical grid and the consumption of the installation Battery electrical storage The ecoSMART e system...

Page 8: ...parameters Figure 3 1 Control panel The general functions of each of the buttons and operation is indicated below The ALARMS menu can be accessed directly from anywhere in the application The list of...

Page 9: ...he controller still run but the alarm warns us of abnormal behavior and registers it 3 4 Operating modes The operating modes active in the ecoSMART e system are reflected in the main screen and give a...

Page 10: ...al ecoSMART e system 8 EN REGULATION signal An output for speed control of the heat pump compressor has been activated NON CRITICAL LOAD ACTIVE signal Relay output to non critical load enabled up to f...

Page 11: ...3 Browsing through the list of user menus XXXXXX XXXXXX XXXXXX 9 Fri 4 5 kW 3 8 kW 4 5 User menu 7 On Off Date and hour Surplus control 4 5 User menu 7 On Off Date and hour Surplus control 4 5 User m...

Page 12: ...nd return to position 1 7 With the cursor in position 1 again press buttons to go to the previous or next screen or to return to the list of user menus Figure 3 4 Adjusting comfort parameters 3 8 ON O...

Page 13: ...independent non critical loads through the output relays of the manager 3 13 INFORMATION Menu Press for quick access to the information men from the main screen Daily saving time Enable Transition ti...

Page 14: ...to the grid and the total energy consumed by the installation with its solar coverage ratio self consumed generated energy for the same Heat pump meters Allows to visualize the electrical energy consu...

Page 15: ...ms This screen displays the active alarms The button illuminates Reset alarms It allows us to reset alarms once solved User menu 7 7 Non critical loads Information Alarms 8 8 Alarms Lost comm with the...

Page 16: ...ith the heat pump Communication with the heat pump has been lost Check that the inverter is on and powered Check the connection of the heat pump with the controller in the panel Make sure the wires ar...

Page 17: ...8 V Battery voltage range 40 60 V Charge max current 50 A Recharge curve 3 stage adapter with maintenance Over current temperature protection Yes Interfaz de comunicaci n Can RS232 Electronic AC power...

Page 18: ...iciency 97 6 Euro efficiency 97 MPPT efficiency 99 9 Safety and protections Overload protection Yes Overtemperature protection Yes Overvoltage undervoltage protection Yes Overload protection category...

Page 19: ...nonconformity For the warranty to be effective the purchaser must present a legal document that supports the date of purchase duly stamped and signed from the establishment that made the sale Disclai...

Page 20: ...NOTES...

Page 21: ......

Page 22: ......

Page 23: ...ontes 25 36350 Nigr n Pontevedra Spain Tel 34 986 262 184 34 986 417 700 Fax 34 986 262 186 e mail Info ecoforest es http www ecoforest es The manufacturer reserves the right to make any necessary cha...

Reviews: