![ECOFOREST Cantina Super Installation And Maintenance Manual Download Page 53](http://html1.mh-extra.com/html/ecoforest/cantina-super/cantina-super_installation-and-maintenance-manual_2354336053.webp)
52
6.26.
If the boiler turns off and there are half burnt pellets in the fire basket, this might be due to a lack of
cleaning. Revise chapter related to cleaning and maintenance.
6.27.
Internal dirt or ongoing use without cleaning.
6.28.
If the boiler is off and there are no pellets in the basket, check the reducer motor, convection motor and
extractor.
ALSO CONSIDER THE FOLLOWING…
MESSAGE
DESCRIPTION
SOLUTIONS
IF NOTHING STARTS-UP.
•
No power supply.
•
Power cable badly connected or cut.
•
Fuse CPU burned.
•
EMI power filter damaged.
•
Make sure there is power.
•
Replace cable.
•
Replace fuse. If the fuse is burnt, this is the
reason why the hardware is cancelled and
there is a short-circuit with a
~
230/240V -
50Hz
item.
Check any possible short-circuits
with a multimeter.
•
Inform your distributor so that he replaces it.
AT START-UP, THE BOILER
PRODUCES A BIP BUT
DISPLAY DOES NOT START.
•
Check connection of keyboard’s belt.
•
Flat belt damaged.
•
Keyboard panel damaged.
•
If it is doubled or deformed, replace it.
•
Replace it.
•
Replace it.
•
Advise your distributor to repair or replace
it.
EVERYTHING
STARTS-UP
BUT KEYBOARD DOES NOT
EXECUTE.
•
Check connection of keyboard’s belt.
•
Flat belt damaged.
•
Keyboard panel damaged.
•
Control unit damaged.
•
If it is doubled or deformed, replace it.
•
Replace it.
•
Replace it.
•
Advise your distributor to repair or replace
it.
AFTER SOME TIME OF
OPERATION, IT INDICATES
CHANGES IN AIR LEVEL
AND PELLETS STACK IN
THE BASKET.
•
The boiler needs air for combustion.
•
Check the Lumber of hours of operation
since last maintenance (Menu 2-5).
•
Check pellets quality.
•
Make sure fireplace door and ashtray basket
are well closed.
•
Carry out maintenance.
•
Replace the bag of pellets by another bag;
make sure it is stored in a dry place.
DOOR OPEN OR ERROR IN
DEPRESSION.
•
As indicated, the fireplace door is open or
there is a failure in the air Redding system
necessary for combustion to happen.
•
Fire place door open.
Close the door.
•
Gas outlet pipe stacked.
Clean gas outlet.
•
Boiler full of ash inside.
Carry out
maintenance.
•
Air entrance pipe stacked.
Clean air Entrance
pipe.
•
Air reading pipe (transparent silicone pipe
linking the Unicontrol to the air inlet pipe),
disconnected or cut.
Connect or replace.
•
Extractor does not turn.
•
Failure in depression reading system of the
Unicontrol, check depression air level, cf.
Menu 3, chapter 1 (S.A.T.)
PUMP DISCONNECTED.
•
The Unicontrol does not detect the pump.
•
If the boiler is new, this might be due to
electric power problems.
•
Check the pump is connected to power
through menu 3 section 0.
•
Check the grey cable going out from the
Unicontrol.
Connect it if necessary.
EXTRACTION
MOTOR
DISCONNECTED.
•
The Unicontrol does not detect the
Extractor.
•
If the boiler is new, this might be due to
electric power problems.
•
Check is power is being supplied to the
exhaust motor through menu 3 section 1.
•
Check the red cable going out from the
Unicontrol.
Connect it if necessary.
Summary of Contents for Cantina Super
Page 2: ...1 22 06 2 012 Página 2 Page 30 Page 57 Pagina 85 Página 113 ...
Page 3: ...2 MANUAL DE INSTALACIÓN Y MANTENIMIENTO ...
Page 31: ...30 INSTALLATION AND MAINTENANCE MANUAL ...
Page 58: ...57 MANUEL D INSTALLATION ET MAINTENANCE ...
Page 86: ...85 MANUALE D INSTALLAZIONE E MANUTENZIONE ...
Page 114: ...113 MANUAL DE INSTALAÇÃO E MANUTENÇÃO ...
Page 182: ...181 23 MEDIDAS MEASURES MESURES MISURES MEDIDAS SUPER INSERT SI 2011 ...
Page 184: ...183 25 MEDIDAS MEASURES MESURES MISURES MEDIDAS MEDIDAS CANTINA SUPER CS 2011 ...
Page 186: ...185 27 MEDIDAS MEASURES MESURES MISURES MEDIDAS HIDROCOPPER SUPER HS 2011 ...
Page 188: ...187 29 MEDIDAS MEASURES MESURES MISURES MEDIDAS HIDROCOPPER HC 2011 ...
Page 190: ...189 31 MEDIDAS MEASURES MESURES MISURES MEDIDAS HIDROCOPPER CERÁMICA HC 2011 ...
Page 192: ...191 33 MEDIDAS MEASURES MESURES MISURES MEDIDAS HIDROCOPPER MINI HB 2011 ...
Page 194: ...193 35 MEDIDAS MEASURES MESURES MISURES MEDIDAS HIDROCOPPER INSERT EH 2010 ...
Page 204: ...203 Página 3 Page 14 Page 25 Pagina 37 Página 48 ...
Page 206: ...205 Manual de usuario ...
Page 217: ...216 User manual ...
Page 228: ...227 Manuel d utilisation ...
Page 240: ...239 Manuale di istruzioni ...