![ECOFOREST Cantina Super Installation And Maintenance Manual Download Page 224](http://html1.mh-extra.com/html/ecoforest/cantina-super/cantina-super_installation-and-maintenance-manual_2354336224.webp)
223
If you activate this MENU when room temperature you settled goes beyond
2°C, the boiler will stop and turn on after room temperature would have gone
down and after the boiler gets cold. In order to activate it, press the increase
button (
V
) and you will see on the screen that it is activated by an
“S”
between fuel level and room temperature.
Example:
If you wish the temperature sensor (thermostat) to control the start and stop of the boiler through
room temperature, put the Stand-By by thermostat on position YES. This function is only recommended in case of
minimal temperature decrease in the house (2°C within 24 hours) as repeated starts and stops may damage the
boiler.
If you wish the boiler to turn on at a higher level than set by default, (level 5) change it at
point 1-5
, to reach
this point, follow previous steps that is, press MENU (
Z
) twice and increase (
V
) until the following is displayed:
When this screen is displayed, press MENU (
Z
).
Programming has to be made through the increase/decrease buttons
(
C V
). Pellets drop level at which you wish the boiler to turn on (1, 3, 5, 7,
9). To exit, press On button (
X
), you get back to point 1-5 pellets level.
If you press On (
X
) you get back to the main screen and if you press increase (
V
) you enter menu 1-6
Combustion air adjustment.
Important: if you request a password to enter, this will be
V V V V V V V V
V V V V V V V V
V V V V V V V V
V V V V V V V V
.
Though the boiler adjusts automatically, fine-tuning might be necessary, for
example, lack of cleaning, dirty heat exchanger, fire-basket full of ash, etc.
Setting is easy: when
point 1-6
is displayed, press MENU (
Z
)
and the
following appears:
Actual combustion air level in millibars, to adjust it, increase it through (
V
) or
decrease it through (
C
). This setting is necessary only in case of problems
related to gas outlet pipe or excessive drawing. It can be increased (+ 0.09) or
decreased (- 0.09) through 9 levels. To exit press On (
X
) and you get back to
point 1-6 Combustion air setting.
If you press MENU (
Z
)
:
In this menu, set the extractor rotation manually: by pressing
increase/decrease buttons (
C V
) you will increase or decrease the power
of the extractor – read point 1-7a air setting – carefully.
Only in air models. If you press MENU (
Z
)
:
In this menu, set the extractor rotation manually: by pressing
increase/decrease buttons (
C V
) you will increase or decrease the speed of
the convection fan.
If you press On (
X
) you get back to the MENU and if you press the increase button (
V
) you reach menu 1-7
Multiple use settings.
Press MENU (
Z
) and you reach this menu.
1-4c Thermostat
Standby NO
1-5 Pellets
level programming
1-5 5 _ _ _
level programming
1-6 Combustion
air adjustment
1-6a Air combus.
adjustm.
.
00 mB
1-6b Adjust turn
extract. 00%
1-6c Fan speed
adjustm. 00%
1-7 Other uses
programming
Summary of Contents for Cantina Super
Page 2: ...1 22 06 2 012 Página 2 Page 30 Page 57 Pagina 85 Página 113 ...
Page 3: ...2 MANUAL DE INSTALACIÓN Y MANTENIMIENTO ...
Page 31: ...30 INSTALLATION AND MAINTENANCE MANUAL ...
Page 58: ...57 MANUEL D INSTALLATION ET MAINTENANCE ...
Page 86: ...85 MANUALE D INSTALLAZIONE E MANUTENZIONE ...
Page 114: ...113 MANUAL DE INSTALAÇÃO E MANUTENÇÃO ...
Page 182: ...181 23 MEDIDAS MEASURES MESURES MISURES MEDIDAS SUPER INSERT SI 2011 ...
Page 184: ...183 25 MEDIDAS MEASURES MESURES MISURES MEDIDAS MEDIDAS CANTINA SUPER CS 2011 ...
Page 186: ...185 27 MEDIDAS MEASURES MESURES MISURES MEDIDAS HIDROCOPPER SUPER HS 2011 ...
Page 188: ...187 29 MEDIDAS MEASURES MESURES MISURES MEDIDAS HIDROCOPPER HC 2011 ...
Page 190: ...189 31 MEDIDAS MEASURES MESURES MISURES MEDIDAS HIDROCOPPER CERÁMICA HC 2011 ...
Page 192: ...191 33 MEDIDAS MEASURES MESURES MISURES MEDIDAS HIDROCOPPER MINI HB 2011 ...
Page 194: ...193 35 MEDIDAS MEASURES MESURES MISURES MEDIDAS HIDROCOPPER INSERT EH 2010 ...
Page 204: ...203 Página 3 Page 14 Page 25 Pagina 37 Página 48 ...
Page 206: ...205 Manual de usuario ...
Page 217: ...216 User manual ...
Page 228: ...227 Manuel d utilisation ...
Page 240: ...239 Manuale di istruzioni ...