WHAT DO TO IF...
THE BOILER REMAINS OUT OF POWER:
6.4.
Make sure the boiler is connected and the plug is leading power.
6.5.
Make sure the cable is not damage or cut.
While the boiler is disconnected, dismantle the right door of the boiler and check if any lead of the C.P.U. is
slack.
6.6.
Check the CPU pilot. If it is OFF, check also the fuse on the CPU.
PELLETS DO NOT FALL AND THE BOILER DOES NOT TURN ON:
6.7.
Check if there are pellets in the hopper.
6.8.
Make sure the glass door is closed.
6.9.
Make sure the gas outlet tube is not obstructed by anything (e.g. bird nest, plastic, etc.).
6.10.
Make sure the exhaust motor works, because if it does not work fuel will not fall.
6.11. With the boiler unplugged,
check that the security thermostat is located in the Hidrocopper models (
drawing
33
) on the inside of the boiler, by opening the side door. To activate it, you must unscrew the cap and press
the button if necessary. If the thermostat is activated you will hear a “click”. In the insert model, you will find
it in the front part (
drawing 34
), under the keyboard. And in the Super Insert model (
drawing 35
) you will find
it behind the left side lining doors.
Drawing 33
Drawing 34
Drawing 35
6.12.
If the reducer motor receives current and rotate slower than usually, it may have something blocked such as
a screw, a piece of wood, etc. To solve this problem, you must empty the hopper and, even if necessary, to
remove the auger screen (contact with technical support).
6.13.
If when the reducer motor rotates makes a noisy is due to a lack of lubrication- you have to lubricate only the
auger screen,
not the reducer motor
, see point
5.16
.
PELLETS FALL BUT THE BOILER DOES NOT TURN ON:
6.14.
Make sure the glass door is well closed.
6.15.
Make sure the burn pot is correctly placed, that it is in contact with the resistance tube and the central hole
of the basket goes along with this tube.
Summary of Contents for Cantina Super
Page 2: ...1 22 06 2 012 Página 2 Page 30 Page 57 Pagina 85 Página 113 ...
Page 3: ...2 MANUAL DE INSTALACIÓN Y MANTENIMIENTO ...
Page 31: ...30 INSTALLATION AND MAINTENANCE MANUAL ...
Page 58: ...57 MANUEL D INSTALLATION ET MAINTENANCE ...
Page 86: ...85 MANUALE D INSTALLAZIONE E MANUTENZIONE ...
Page 114: ...113 MANUAL DE INSTALAÇÃO E MANUTENÇÃO ...
Page 182: ...181 23 MEDIDAS MEASURES MESURES MISURES MEDIDAS SUPER INSERT SI 2011 ...
Page 184: ...183 25 MEDIDAS MEASURES MESURES MISURES MEDIDAS MEDIDAS CANTINA SUPER CS 2011 ...
Page 186: ...185 27 MEDIDAS MEASURES MESURES MISURES MEDIDAS HIDROCOPPER SUPER HS 2011 ...
Page 188: ...187 29 MEDIDAS MEASURES MESURES MISURES MEDIDAS HIDROCOPPER HC 2011 ...
Page 190: ...189 31 MEDIDAS MEASURES MESURES MISURES MEDIDAS HIDROCOPPER CERÁMICA HC 2011 ...
Page 192: ...191 33 MEDIDAS MEASURES MESURES MISURES MEDIDAS HIDROCOPPER MINI HB 2011 ...
Page 194: ...193 35 MEDIDAS MEASURES MESURES MISURES MEDIDAS HIDROCOPPER INSERT EH 2010 ...
Page 204: ...203 Página 3 Page 14 Page 25 Pagina 37 Página 48 ...
Page 206: ...205 Manual de usuario ...
Page 217: ...216 User manual ...
Page 228: ...227 Manuel d utilisation ...
Page 240: ...239 Manuale di istruzioni ...