![ECOFOREST Cantina Super Installation And Maintenance Manual Download Page 35](http://html1.mh-extra.com/html/ecoforest/cantina-super/cantina-super_installation-and-maintenance-manual_2354336035.webp)
34
4.
INSTALLATION.
The below security distances and assembly diagrams are given for information only as an adaptation shall be
made depending on the norms in force regarding gas outlet, power, security minimum distances specific to
geographic areas.
The installation of the boilers must be done in the same way, for this reason, only the HIdrocopper model
will be exposed. In the same way, air inlets and water connections will be missed in all drawings as section 4.10
indicates the minimum security distances to be respected for their installation.
UNPACKING THE BOILER.
4.1.
Remove the wooden box and the plastic protecting the boiler.
4.2.
Remove the screws that tie the boiler to the pallet.
4.3.
If our model has a plastic protection, it must be removed before starting it.
4.4.
In you have purchase a ceramic model; you must consider that ceramics is sent in cardboard boxes properly
protected.
In ceramic models the assembly order is shown in
drawing 1
. Ceramic columns should only be hanged on the
supports situated in the boiler itself.
Drawing 1
MATERIAL REQUIRED FOR INSALLATION.
4.5.
Mandatory:
Stainless steel flex (AISI 316),
never
use aluminium.
4.6.
In cases of humidity in the atmosphere above 60% is highly recommended installing a double-walled pipe of
stainless steel.
4.7.
If the boiler is to be installed in a wooden house, it is
compulsory
to have a double-walled flex.
4.8.
If the boiler is going to be mounted in a French-style fireplace, use a flexible tube of stainless steel for the gas
outlet, fexible braided hoses for the hydraulic conections and a cover plate to avoid the gas reverse.
4.9.
Aluminium belt and silicone of high temperature (300
°
C).
SECURITY NORMS FOR GAS OUTPUT AND AIR INPUT.
4.10.
Gas output must be located in a ventilated area, not in closed or half-closed areas e.g. garage, corridor, air
space of the house or places where gas may concentrate.
4.11.
The external parts of the boiler may reach high temperatures that might burn when touching; it is
recommended to use a non flammable grid to avoid risk of burn for children and old people.
Summary of Contents for Cantina Super
Page 2: ...1 22 06 2 012 Página 2 Page 30 Page 57 Pagina 85 Página 113 ...
Page 3: ...2 MANUAL DE INSTALACIÓN Y MANTENIMIENTO ...
Page 31: ...30 INSTALLATION AND MAINTENANCE MANUAL ...
Page 58: ...57 MANUEL D INSTALLATION ET MAINTENANCE ...
Page 86: ...85 MANUALE D INSTALLAZIONE E MANUTENZIONE ...
Page 114: ...113 MANUAL DE INSTALAÇÃO E MANUTENÇÃO ...
Page 182: ...181 23 MEDIDAS MEASURES MESURES MISURES MEDIDAS SUPER INSERT SI 2011 ...
Page 184: ...183 25 MEDIDAS MEASURES MESURES MISURES MEDIDAS MEDIDAS CANTINA SUPER CS 2011 ...
Page 186: ...185 27 MEDIDAS MEASURES MESURES MISURES MEDIDAS HIDROCOPPER SUPER HS 2011 ...
Page 188: ...187 29 MEDIDAS MEASURES MESURES MISURES MEDIDAS HIDROCOPPER HC 2011 ...
Page 190: ...189 31 MEDIDAS MEASURES MESURES MISURES MEDIDAS HIDROCOPPER CERÁMICA HC 2011 ...
Page 192: ...191 33 MEDIDAS MEASURES MESURES MISURES MEDIDAS HIDROCOPPER MINI HB 2011 ...
Page 194: ...193 35 MEDIDAS MEASURES MESURES MISURES MEDIDAS HIDROCOPPER INSERT EH 2010 ...
Page 204: ...203 Página 3 Page 14 Page 25 Pagina 37 Página 48 ...
Page 206: ...205 Manual de usuario ...
Page 217: ...216 User manual ...
Page 228: ...227 Manuel d utilisation ...
Page 240: ...239 Manuale di istruzioni ...