12.  If flexible suction lines are used be sure their selection and installation will prevent 

wall collapse and thus a starved suction condition. 

13.  When taking suction from a tank or vessel, avoid entry of sludge, solids, etc. into 

suction line by placing suction line inlet above maximum expected level of solids. 

14.  Discharge lines from Gearchem pumps should be fitted with properly sized relief 

valves to protect both pump and discharge system. Relief valve outlet should be 
piped back to suction vessel. 

15.  When a by-pass system is used to control flow from the pump, the bypassed fluid 

should be piped back to the suction vessel to prevent heat build-up due to 
recirculation. If it is absolutely necessary to pipe by-pass back to the pump suction 
line, the point of entry should be at least 10 pipe diameters away from the suction 
inlet. Provision for cooling should be made in the event of excessive heat buildup 
through fluid recirculation. 

16.  Where pumped fluids may solidify, crystalize, precipitate etc., provision should be 

made to thoroughly flush pump and piping during periods of shutdown. Pay particular 
attention to proper flushing of seal or stuffing box area. 

3.1  MECHANICAL SEALS

 

Three basic seal types are offered as standard: internal, external, and double seal. All 
mechanical seals require cooling and lubrication. For long and trouble-free seal life: 

1.  Do not run pump dry. Make sure pump is primed, suction is not starved, sufficient 

NPSH is available and your system is such that seal surfaces are wet. If a seal flush 
system is used, make sure that it is operating while the pump is operating. Double 
seals require a seal flush. 

2.  Keep abrasives out of the seal area. Dirty flush streams, whether piped from the 

pump discharge or from a separate source, will destroy the rotating and stationary 
seal mating surfaces. 

3.  Make sure pump and driver are properly aligned. Misaligned seal mating surfaces will 

not function. Excessive vibration will also prevent proper seal function and cause 
early failure. 

4.  Determine that seal materials of construction are compatible with pumped fluid. Be 

sure to check this when changing application. 

3.2  PACKED STUFFING BOXES 

The basic housekeeping procedures for mechanical seals also apply to packed pumps. 
For proper operation, the stuffing box area must be cooled and lubricated. Do not 
overtighten packing. Where packing lubricant IS required, use it. Run in new packing 
carefully. Care and time taken at this stage will minimize down time and maintenance 
costs. Misalignment and vibration also shorten packing life. Flush streams to lantern ring 
stuffing boxes are as important as flush streams to mechanical seals. 

  

4.  OPERATION 

1.  Prior to operation, recheck installation according to instructions. Be sure electrical 

service to motor agrees with nameplate requirements. Jog to check rotation and 
rewire motor if necessary. 

2.  Lubricate packing, if required, using suitable lubricant. Where pump is equipped with 

lantern ring stuffing box and recirculating flush check for proper piping from pump 
discharge to lantern ring nipple. Where thorough flush of lantern ring stuffing box is 
intended, check flush stream piping to and from stuffing box. 

3.  Check mechanical seal flush arrangements where used. Pressurized flush to double 

seal chamber must be in operation, at an inlet pressure of 10 to 15 psi above 
intended pump discharge pressure, prior to and when operating pump. Flush must 

Summary of Contents for GA Series

Page 1: ...ECO GEARCHEM PUMPS GA GC SERIES Installation Operation Maintenance Manual Bulletin IOM ECO 3000 REV C...

Page 2: ...ty repairs will be subject to bench fees and costs associated with replacement parts TRADEMARKS ECO is a registered trademark of Pulsafeeder Inc Pulsafeeder is a registered trademark of Pulsafeeder In...

Page 3: ...QUIPMENT EASIER REVISION HISTORY Revision Implemented By Revision Date Approved By Approval Date Reason B Kristin Lenzi June 2021 Phuoc Pham 6 7 2021 New format General update Recommended torque value...

Page 4: ...DISASSEMBLY 10 5 3 REASSEMBLY 12 5 4 BOLT ON THERMAL JACKETS INSTALLATION 14 5 5 REMOVAL 15 6 TROUBLESHOOTING 16 7 TORQUE CHART 17 8 PUMP SPECIFICATION CHART 18 9 EXPLODED VIEW DRAWING G2 G4 SERIES 1...

Page 5: ...ributor for details Field repairs can be done very quickly using an Eco KOPkit which includes all the parts necessary to cover practically all routine maintenance requirements 2 EQUIPMENT INSPECTION 1...

Page 6: ...Use only full bore ball valves or gate valves in the suction piping If suction strainers are required size them to minimize pressure drop and select those of a type that are easily cleaned 5 Arrange...

Page 7: ...uble seals require a seal flush 2 Keep abrasives out of the seal area Dirty flush streams whether piped from the pump discharge or from a separate source will destroy the rotating and stationary seal...

Page 8: ...ll determine future maintenance intervals For motor maintenance instructions consult the motor manufacturer WARNING BEFORE PERFORMING ANY MAINTENANCE REQUIRING PUMP DISASSEMBLY BE SURE TO FLUSH PUMP T...

Page 9: ...sive contact Dimensions and directions are given for each model in the Reassembly Section F A seal flush must be used for all double seal installations The flush must be clean and introduced at a pres...

Page 10: ...rive Shaft Idler Shaft Drive Gear Idler Gear Drive Gear Key Idler Gear Key Bearings Wear Plates Bearing Lock Pins Housing 0 Rings Drive Gear Retaining Rings Idler Gear Retaining Rings Shaft Seal Arran...

Page 11: ...so as to give access to seal head set screws Rotate shaft to allow access to seal head set screws and loosen set screws to allow removal of seal head Item 60 With G6 pumps seal housing must be unscre...

Page 12: ...the idler gear 2 Install new bearings Items 12 13 in both the front and rear housing Make sure that bearing lock pins Item 14 are installed on each bearing 3 Install 2 new O rings Item 16 in the groov...

Page 13: ...D with oil or TFE spray Carefully and gently push seal head over shaft taking care not to damage TFE wedge or seal face 6 Pull shaft away from pump as far as built in end play will allow it then full...

Page 14: ...operly rotate shaft by hand several times Remove front drive bearing flush plug to observe pump end of shaft Observe shaft and gland at coupling end There should be zero leakage from either end 5 4 BO...

Page 15: ...s with suitable wrenches IF JACKET HALVES ARE BEING REMOVED TO REPAIR THE PUMP OR REPLACE IT WITH AN IDENTICAL COMPONENT AND FLEXIBLE METAL HOSES ARE USED AS JUMPOVERS IT IS NORMALLY UNNECESSARY TO RE...

Page 16: ...ft too high Air or gas in liquid Pump worn or damaged Locate and repair leak Increase suction pressure Eliminate air or gas Install or clean strainer in inlet pipe Pump noisy Pump cavitating Pump worn...

Page 17: ...8 Motor Adaptor Bolt 3 8x16 120 13 5 G6 GA6 Rear Housing Bolts 1 4x28 60 6 8 Gland Nut Bolts 1 4x20 60 6 8 GC6 Rear Housing Bolts 1 4x28 60 6 8 Gland Nut Bolts 1 4x20 60 6 8 Motor Adaptor Bolt 3 8x16...

Page 18: ...18 8 PUMP SPECIFICATION CHART...

Page 19: ...19 9 EXPLODED VIEW DRAWING G2 G4 SERIES...

Page 20: ...20 10 EXPLODED VIEW DRAWING G6 G8 SERIES...

Page 21: ...21 11 EXPLODED VIEW DRAWING GH8 SERIES...

Page 22: ...22 12 EXPLODED VIEW DRAWING GA12 GA16 SERIES...

Page 23: ...23 13 SEAL ARRANGEMENT DRAWINGS...

Page 24: ...24...

Page 25: ...25...

Page 26: ...26...

Page 27: ...27...

Page 28: ...lf to motor half optional wrap coupling jaws and spider with masking tape 3 Slide shaft of pump assembly into coupling mounted on motor fasten pump adaptor to motor with bolts provided 4 By using coup...

Page 29: ...29 15 GEARCHEM PUMP PRESSURES...

Page 30: ...30...

Page 31: ...ilable in oil metallurgies 6 Double mechanical seals must be pressurized with seal fluid 15 to 20 psig above the pump discharge pressure 7 Standard GA12 and GA16 pumps furnished with bearing flush por...

Page 32: ...32...

Page 33: ...33...

Page 34: ...cal seals must be pressurized with seal fluid 15 to 20 psig above the pump discharge pressure 7 Standard GA12 pumps furnished with bearing flush ports metallic bearing lock pins and slotted wear plate...

Page 35: ...35 15 PUMP PERFORMANCE CURVES...

Page 36: ...36...

Page 37: ...37...

Page 38: ...38...

Page 39: ...39...

Page 40: ...40...

Page 41: ...41...

Page 42: ...42...

Page 43: ...43...

Page 44: ...44...

Page 45: ...45...

Page 46: ...46...

Page 47: ...47...

Page 48: ...48...

Page 49: ...49...

Page 50: ...50...

Page 51: ...51...

Page 52: ...52...

Page 53: ...53...

Page 54: ...54...

Page 55: ...55...

Page 56: ...56...

Page 57: ...57...

Page 58: ...58...

Page 59: ...59 Pulsafeeder Inc 2883 Brighton Henrietta Town Line Road Rochester NY 14623 1 585 292 8000 www pulsa com...

Reviews: