6.3. IR Sensor and IR Blaster
7.
INSTALLATION AND CONFIGURATION
When VEO-XTI1C and VEO-XRI1C are connected as simple extension in a point-to-
point connection through a single Cat5e/6 cable, no configuration is needed. When
devices are connected to a standard Ethernet LAN in point-to-multipoint or multipoint-
to-multipoint topologies, please make sure that every device has unique IP address and
every transmitter is using a unique Group ID.
7.1. IP Address Settings
7.1.1. Static IP Address Configuration
When static IP addresses are required, the IP address of each device needs to be set
manually. The default IP address for transmitters and receivers is:
VEO-XTI1C:
192.168.1.11
VEO-XRI1C:
192.168.1.12
The IP address can be changed using the embedded web page or using the utility
software. For web page access, be sure that PC and VEO devices are in the same
Network Domain and just type the default IP address in your internet browser. The
default credentials for login are:
User name:
admin
Password
:
admin
After changing default Ethernet settings press the related “Update” button and Reboot
the unit.