background image

Page 2 of 8

Carefully remove the microbar and place it on a flat surface. Examine the unit for transit damage, and locate all parts. If damage is found, or 

parts are missing, contact the transit company or ECCO. Do not use damaged or broken parts.

Installation and Mounting:

3 Mount Options:

1. 

Direct bolt on flat surface.

2. 24” and 48” lengths include mounting feet and carriage bolts.

3. 

12” length includes headache rack brackets. Customer to supply center bolt (5/16” carriage or 3/8” standard).

IMPORTANT! This unit is a safety device and it must be connected to its own separate, fused power point to assure its continued operation 

should any other electrical accessory fail.

CAUTION!

When drilling into any vehicle surface, make sure that the area is free from any electrical wires, fuel lines, vehicle upholstery, etc. that 

could be damaged.

Permanent Mounting:

Magnet Mounting:

Flash Pattern Selection:

To select a flash pattern, apply power to the RED or WHITE or both RED and WHITE wires. (WHITE wire is for dual color only.) Momentarily 

touch the BLUE wire to the BLACK wire (ground) for less than 1 second to advance to the next pattern. To go back to the previous pattern, 

momentarily touch the BLUE wire to the BLACK wire for approximately 2 - 3 seconds. To force the flash pattern to STEADY, momentarily 

touch the BLUE wire to the BLACK wire for approximately 5 seconds. When Vacuum-Magnet Mount is being used, the BLUE wire is 

connected to ground via the momentary switch on the cigarette plug as shown in FIGURE 2. For more detail about flash patterns, please see 

the SINGLE and DUAL COLOR FLASH PATTERN TABLES below.

Flash Pattern Synchronization:

The permanent mount microbars sync with compatible Code 3 products via the yellow wire:

Step 1.  

Determine the desired style of flash pattern for each unit and set each unit individually (without the yellow wires connected together) 

to avoid confusion. It is also strongly recommended that the same style of flash pattern be used on all units to produce the most effective 

warning pattern. (NOTE: Phases A and B for each style of flash pattern in the table denote the relative timing between units connected in a 

synchronizing installation. To operate simultaneously, each unit must be set to the same phase (A + A or B + B); to operate alternately, units 

must be set to have the opposite phase (A + B or B + A)).

Step 2.  

Connect the yellow sync wires together and check that the units are flashing in a synchronized manner as expected. If a pattern 

on one unit appears incorrect, the blue pattern select wire can be used to cycle forward or backward on that individual unit until the correct 

pattern is selected. Note: This will only change the pattern in the one unit and will not affect the other units connected to the yellow sync wire.

Step 3.  

If the yellow wire is unused, leave unconnected and insulated.

Dimming Feature:

To activate the dimming feature of this lightbar, attach the BLUE wire to the RED wire (+BATT).

1. Slide bolts into channel on bottom side of bar. 

2. Install brackets onto bolts with provided nuts and washers.

WARNING!

Maximum recommended vehicle speed for safe operation 

using the Vacuum Mount model is 65 mph (104 km/h) when 

fitted to the center of a vehicle roof of steel construction.  Higher 

speeds could cause the mount to fail, resulting in the minibar flying 

off of the vehicle, which could cause damage to other vehicles and 

injury or death to the passengers.  The vacuum-magnet mount is 

not intended as a permanent mount for the minibar.  The vacuum-

magnet mount unit must be mounted on a magnetic surface (i.e. no 

fiberglass, etc.).  Ensure that the magnet ts kept clean.

Summary of Contents for REFLEXL 11 Series

Page 1: ...uct so that output performance of the system is maximized and the controls are placed within convenient reach of the operator so that they can operate the system without losing eye contact with the ro...

Page 2: ...via the yellow wire Step 1 Determine the desired style of flash pattern for each unit and set each unit individually without the yellow wires connected together to avoid confusion It is also strongly...

Page 3: ...method of making electrical connections and splices to protect these points from corrosion and loss of conductivity 5 Ground termination should only be made to substantial chassis components preferab...

Page 4: ...lass 1 Class 1 11 Double 120 Y B Class 1A Class 1A Class 1A Class 1A Class 1 Class 1 Class 1 Class 1 12 Double Alternating Split 120 Y 13 Quad 75 Y A Class 1A Class 1A Class 1A Class 1A 14 Quad 75 Y B...

Page 5: ...s 1A 8 8 16 Single Color 1 then 2 120 Y A 9 9 17 Single Color 1 then 2 375 Y B 10 10 18 Single Split Alternating Color 1 then 2 375 Y 11 19 Double Color 1 75 Y A Class 1A Class 1A Class 1A Class 1A Cl...

Page 6: ...47 Quad Color 1 75 Y B Class 1A Class 1A Class 1A Class 1A Class E Class E Class E 48 Quad Split Color 1 2 75 Y A 49 Quad Split Color 1 2 75 Y B 25 50 Quad Color 2 75 Y A Class 1A Class 1A Class 1A C...

Page 7: ...olor 1 then 2 150 Y A 75 Quad Diagonal Split Alternating Color 1 then 2 150 Y B 39 76 Quad Diagonal Color 2 150 Y A 40 77 Quad Diagonal Color 2 150 Y B 41 41 78 Quad Diagonal Alternating Color 1 then...

Page 8: ...nties MANUFACTURER MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED THE IMPLIED WARRANTIES FOR MERCHANTABILITY QUALITY OR FITNESS FOR A PARTICULAR PURPOSE OR ARISING FROM A COURSE OF DEALING USAGE OR TRAD...

Page 9: ...o el contacto visual con la calzada 5 No instale este producto ni coloque los cables en la zona de despliegue de un airbag Si el equipo se monta o coloca en la zona de despliegue de un airbag el airba...

Page 10: ...1 1 Determine el estilo del patr n de destello deseado para cada unidad y ajuste cada unidad de forma individual sin los cables amarillos conectados entre s para evitar confusiones Tambi n se recomie...

Page 11: ...dispositivos 4 Se debe prestar especial atenci n a la ubicaci n y el m todo para realizar conexiones y empalmes el ctricos con el fin de proteger estos puntos de la corrosi n y de la p rdida de conduc...

Page 12: ...TAS LAS GARANT AS IMPL CITAS PARA LA COMERCIALIZACI N CALIDAD O ADECUACI N CON UN PROP SITO ESPEC FICO O QUE SURJAN DEL CURSO DE NEGOCIACIONES USO O PR CTICA COMERCIAL QUEDAN POR LA PRESENTE EXCLUIDAS...

Page 13: ...pement install ou situ dans la zone de d ploiement d un sac gonflable peut r duire l efficacit de ce dernier ou devenir un projectile pouvant causer des blessures corporelles graves voire mortelles Co...

Page 14: ...enir l effet pr c dent faites bri vement entrer en contact le fil BLEU et le fil NOIR de 2 3 secondes Pour forcer le clignotement l effet STEADY constant faites bri vement entrer en contact le fil BLE...

Page 15: ...t est illustr la figure 6 Tout le c blage doit tre d un calibre minimal de 18 AWG La ligne positive doit tre munie d un fusible de 5 A comme illustr Un interrupteur peut tre utilis pour commander la f...

Page 16: ...R QUAND NON UTILIS 5 A Fusible fourni par l utilisateur BLANC POSITIF COULEUR 2 NOIR Masse S RIE UN MONOCHROME S rie bicolore COMMUTATEUR POUR DIM 5 A Fusible fourni par l utilisateur Commutateur four...

Page 17: ...ALIT MARCHANDE DE QUALIT OU D AD QUATION UN USAGE PARTICULIER OU D COULANT D UNE CONDUITE COMMERCIALE D UNE UTILISATION OU D UNE PRATIQUE COMMERCIALE SONT PAR LES PR SENTES EXCLUES ET NE S APPLIQUENT...

Page 18: ...bereich eines Airbags und verlegen Sie dort auch keine Kabel Ger te die sich im Entfaltungsbereich eines Airbags befinden bzw dort montiert sind beeintr chtigen m glicherweise die Wirksamkeit des Airb...

Page 19: ...en werden um den weiteren Betrieb bei Ausfall eines anderen elektrischen Zubeh rs zu gew hrleisten ACHTUNG Achten Sie beim Bohren in eine Fahrzeugoberfl che darauf dass der Bereich frei von elektrisch...

Page 20: ...Sie es Dimmfunktion Um die Dimmfunktion dieser Mikroleiste zu aktivieren verbinden Sie das BLAUE Kabel mit dem ROTEN Kabel Pluspol der Batterie Anweisungen zur Verkabelung Die Verkabelung der Mikrole...

Page 21: ...ITIV FARBE 1 WEISS POSITIV FARBE 2 EINFARBIGE SERIE Zweifarbige Serie SCHALTER F R DIM 5 A SICHERUNG vom Kunden bereitgestellt Schalter vom Kunden bereitgestellt Schalter vom Kunden bereitgestellt Sch...

Page 22: ...MARKTG NGIGKEIT QUALIT T ODER EIGNUNG F R EINEN BESTIMMTEN ZWECK ODER DIE SICH AUS DEM REGELM SSIGEN GESCH FTSGANG DER NUTZUNG ODER DES HANDELSBRAUCHS ERGEBEN WERDEN HIERMIT AUSGE SCHLOSSEN UND GELTEN...

Reviews: