XN300 switch XN-332-5ETH-UMS

InstructIon manual

   MN050011EN   August 2022   www.eaton.com

Before starting with the installation

 

De-energize the device

 

Secure against retriggering

 

Verify isolation from the supply

 

Ground and short-circuit

 

Cover or enclose any neighboring live parts

 

Follow the mounting instructions (AWA/IL) for the device

 

Only suitably qualified personnel in accordance with  

EN 50 110-1/-2 (VDE 0105 Part 100) may work on this 

device/system

 

Before installation and before touching the device, ensure 

that you are free of electrostatic charge

 

The functional earth (FE) must be connected to the 

protective earth (PE) or to the equipotential bonding.  

The system installer is responsible for implementing  

this connection

 

Connecting cables and signal lines should be installed in 

such a way that inductive and capacitive interference will 

not have a negative impact on the automation functions

 

Install automation devices and related operating elements 

in such a way that they are well protected against 

unintentional operation

 

Suitable safety hardware and software measures should 

be implemented for the I/O interface so that cable or wire 

breakage on the signal side will not result in undefined 

states in the automation devices

 

Ensure a reliable electrical isolation of the low voltage  

for the 24 V supply; only use power supply units 

complying with IEC 60364-4-41 or HD 384.4.41 S2  

(VDE 0100 Part 410)

 

Deviations of the mains voltage from the nominal 

value must not exceed the tolerance limits given in the 

specifications, otherwise this may result in malfunction 

and hazardous states

 

Emergency stop devices complying with IEC/EN 60204-1 

must remain functional in all of the automation devices’ 

operating modes; unlatching the emergency stop devices 

must not result in an automatic restart

 

Built-in devices for enclosures or cabinets must only be 

run and operated in an installed state; desktop devices 

and portable devices only when the housing is closed

 

Measures should be taken to ensure the proper restarting 

of programs interrupted after a voltage dip or outage. This 

should not result in dangerous operating states even for a 

short time; if necessary, emergency stop devices should 

be implemented

 

Wherever faults in the automation system may cause 

damage to persons or property, external measures must 

be implemented to ensure a safe operating state in the 

event of a fault or malfunction (for example, by means of 

separate limit switches, mechanical interlocks, etc.)

Summary of Contents for XN300

Page 1: ...Instruction manual XN300 switch XN 332 5ETH UMS...

Page 2: ...AR PURPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUMENT S...

Page 3: ...and abbreviations vi Writing conventions vi XN300 SWITCH XN 332 5ETH UMS 1 Proper use 1 Overview of functions 1 Versions 1 Ethernet connections 2 LED status indicators 2 Potential relationship betwee...

Page 4: ...ic tasks and procedures are located throughout the manual DANGER HAZARDOUS VOLTAGE CONTACT WITH HAZARDOUS VOLTAGE WILL CAUSE DEATH OR SEVERE PERSONAL INJURY FOLLOW ALL LOCALLY APPROVED SAFETY PROCEDUR...

Page 5: ...or wire breakage on the signal side will not result in undefined states in the automation devices Ensure a reliable electrical isolation of the low voltage for the 24 V supply only use power supply un...

Page 6: ...es The devices described here must only be set up and operated as specified in this manual and in the installation instructions provided with the device Installation commissioning operation maintenanc...

Page 7: ...E G UNEXPECTED MOTOR STARTUPS AND EQUIPMENT BECOMING UNEXPECTEDLY ENERGIZED Overview of functions The XN 332 5ETH UMS XN300 switch features the same design as the other devices in the XN300 system The...

Page 8: ...status indicators The device s status LEDs are located underneath the front cover and can be seen underneath the corresponding labels when they light up Table 1 LED meanings LED Color EtherCAT status...

Page 9: ...must be installed in a horizontal position module designation on top In order to ensure that the maximum operating ambient temperature will not be exceeded make sure that there is enough clearance bet...

Page 10: ...screwdriver to do this Figure 6 Locking the XN 332 5ETH UMS into place on the DIN rail Step 7 Check to make sure that the XN 332 5ETH UMS is solidly mounted Dismantling XN 332 5ETH UMS To remove the...

Page 11: ...ctor simply needs to be slid into the appropriate contact In order to release the conductor simply press on the release mechanism e g with a screwdriver to pull out the conductor from the correspondin...

Page 12: ...ecessary to make sure that a total current of 4 A is not exceeded per terminal External 24 Vdc voltages can also be distributed using an XN 322 4PS 20 power distribution module or XN 322 18PD P and XN...

Page 13: ...462 XN 312 XN 322 E135462 NA certification cULus Protection type IEC IP20 Dimensions All XN300 system devices have the exact same dimensions Description Specification Dimensions W x H x D mm 25 x 101...

Page 14: ...installed between the power supply and the end device Cable cross sections Cable cross sectional areas XN 332 0 39 inch 10 mm Solid mm2 0 2 1 5 0 39 inch 10 mm Flexible with uninsulated ferrule mm2 0...

Page 15: ...9 Instruction manual MN050011EN August 2022 www eaton com...

Page 16: ...rd Cleveland OH 44122 United States Eaton com 2022 Eaton All Rights Reserved Printed in USA Publication No MN050011EN Z26444 August 2022 Eaton is a registered trademark All trademarks are property of...

Reviews: