background image

vi

About this manual

InstructIon manual

   MN050011EN   August 2022   www.eaton.com

About this manual

This manual describes the installation and commissioning  

of the XN300 switch XN-332-5ETH-UMS.

Support center

The latest version of this manual can be found in  

other languages by visiting our support center at:  

http://www .eaton .eu/documentation

.

Enter the search keyword 

XN300

 into the quick search or  

enter the document designation, e.g., MN050011.

List of revisions

This is the first version of this document, meaning there are 

no changes.

Target group

This manual is intended for automation technicians and 

engineers.
Extensive knowledge of how to work with the field bus 

being used will make it easier to understand the contents of 

this manual.
A specialist knowledge of electrical engineering is needed 

for commissioning and programming.

Legal disclaimer

All information in this operator manual was provided by us 

to the best of our knowledge and belief and in accordance 

with the current state-of-the-art. However, this does not 

exclude the possibility of inaccuracies so that we cannot 

accept any liability for the accuracy and completeness of 

the information. In particular, this information does not 

guarantee any particular properties.
The devices described here must only be set up and 

operated as specified in this manual and in the installation 

instructions provided with the device. Installation, 

commissioning, operation, maintenance, and refitting 

of the devices must only be carried out by qualified 

persons. The devices must only be used in the areas 

recommended and only in conjunction with third-party 

devices and components that have been approved by 

us. Only devices and components that are in technically 

faultless conditions are permitted. Fault-free and safe 

operation of the system requires proper transport, storage, 

installation, and commissioning, as well as careful operation 

and maintenance. If the following safety instructions are 

not observed, particularly with regard to commissioning 

and maintenance of the devices by insufficiently qualified 

personnel and/or in the event of improper use of the 

devices, any hazards caused by the devices cannot be 

excluded. We assume no liability for any injury or damages 

incurred.

Device designations and abbreviations

XN300 device series, including the XN-312 gateways and 

XN300 slice modules.

Writing conventions

Symbols used in this manual have the following meanings:

 

DANGER

WARNS OF HAZARDOUS SITUATIONS THAT RESULT IN SERIOUS 

INJURY OR DEATH.

 CAUTION

WARNS OF THE POSSIBILITY OF HAZARDOUS SITUATIONS THAT 

COULD RESULT IN SLIGHT INJURY OR EVEN DEATH.

NOTICE

WARNS ABOUT THE POSSIBILITY OF MATERIAL DAMAGE.

Summary of Contents for XN300

Page 1: ...Instruction manual XN300 switch XN 332 5ETH UMS...

Page 2: ...AR PURPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUMENT S...

Page 3: ...and abbreviations vi Writing conventions vi XN300 SWITCH XN 332 5ETH UMS 1 Proper use 1 Overview of functions 1 Versions 1 Ethernet connections 2 LED status indicators 2 Potential relationship betwee...

Page 4: ...ic tasks and procedures are located throughout the manual DANGER HAZARDOUS VOLTAGE CONTACT WITH HAZARDOUS VOLTAGE WILL CAUSE DEATH OR SEVERE PERSONAL INJURY FOLLOW ALL LOCALLY APPROVED SAFETY PROCEDUR...

Page 5: ...or wire breakage on the signal side will not result in undefined states in the automation devices Ensure a reliable electrical isolation of the low voltage for the 24 V supply only use power supply un...

Page 6: ...es The devices described here must only be set up and operated as specified in this manual and in the installation instructions provided with the device Installation commissioning operation maintenanc...

Page 7: ...E G UNEXPECTED MOTOR STARTUPS AND EQUIPMENT BECOMING UNEXPECTEDLY ENERGIZED Overview of functions The XN 332 5ETH UMS XN300 switch features the same design as the other devices in the XN300 system The...

Page 8: ...status indicators The device s status LEDs are located underneath the front cover and can be seen underneath the corresponding labels when they light up Table 1 LED meanings LED Color EtherCAT status...

Page 9: ...must be installed in a horizontal position module designation on top In order to ensure that the maximum operating ambient temperature will not be exceeded make sure that there is enough clearance bet...

Page 10: ...screwdriver to do this Figure 6 Locking the XN 332 5ETH UMS into place on the DIN rail Step 7 Check to make sure that the XN 332 5ETH UMS is solidly mounted Dismantling XN 332 5ETH UMS To remove the...

Page 11: ...ctor simply needs to be slid into the appropriate contact In order to release the conductor simply press on the release mechanism e g with a screwdriver to pull out the conductor from the correspondin...

Page 12: ...ecessary to make sure that a total current of 4 A is not exceeded per terminal External 24 Vdc voltages can also be distributed using an XN 322 4PS 20 power distribution module or XN 322 18PD P and XN...

Page 13: ...462 XN 312 XN 322 E135462 NA certification cULus Protection type IEC IP20 Dimensions All XN300 system devices have the exact same dimensions Description Specification Dimensions W x H x D mm 25 x 101...

Page 14: ...installed between the power supply and the end device Cable cross sections Cable cross sectional areas XN 332 0 39 inch 10 mm Solid mm2 0 2 1 5 0 39 inch 10 mm Flexible with uninsulated ferrule mm2 0...

Page 15: ...9 Instruction manual MN050011EN August 2022 www eaton com...

Page 16: ...rd Cleveland OH 44122 United States Eaton com 2022 Eaton All Rights Reserved Printed in USA Publication No MN050011EN Z26444 August 2022 Eaton is a registered trademark All trademarks are property of...

Reviews: