background image

INSTALLATION AND OPERATION MANUAL 

CNGE2FE8MSPOE2

MANAGED ETHERNET SWITCH WITH (8) 10/100 BASE-TX  

+ (2) 10/100/1000 BASE-TX/FX COMBO PORTS  

AND POWER OVER ETHERNET (POE)

The ComNet

  CNGE2FE8MSPOE2 is a hardened Managed Ethernet Switch. It 

provides IEEE 802.3af (15W) PoE to eight 10/100BASE-T(X) ports and has two-
gigabit combination SFP or RJ-45 ports. Up to 120 watts of PoE power is available 
for distribution across all 8 TX ports. All SFP ports utilize ComNet SFP* modules for 
fiber and connector type and distance. The CNGE2FE8MSPOE2 is a redundant switch 
offering multiple Ethernet redundancy protocols, C-Ring (recovery time <10ms over 
250 units of connection), ComRing, and MSTP/RSTP/STP (IEEE 802.1 s/w/D). This 
redundancy feature protects your applications from network interruptions or temporary 
malfunctions by redirecting transmission within the network. Network management 
is supported by eConsole, a powerful, easy-to-use Windows-based utility, as well as 
Web-based telnet, and Console (CLI) configurations. This environmentally hardened 
switch is designed for direct deployment in difficult out-of-plant or roadside operating 
environments.

Rev. 4.23.14

Summary of Contents for CNGE2FE8MSPOE2

Page 1: ...for fiber and connector type and distance The CNGE2FE8MSPOE2 is a redundant switch offering multiple Ethernet redundancy protocols C Ring recovery time 10ms over 250 units of connection ComRing and MSTP RSTP STP IEEE 802 1 s w D This redundancyfeatureprotectsyourapplicationsfromnetworkinterruptionsortemporary malfunctions by redirecting transmission within the network Network management is support...

Page 2: ...ions 9 Hardware Installation 10 Installing Switch on DIN Rail 10 Mount Series on DIN Rail 11 Wall Mounting Installation 12 Mounting the CNGE2FE8MSPOE2 on a Wall 12 Hardware Overview 13 Front Panel 13 Front Panel LEDs 15 Top view Panel 16 Rear Panel 17 Cables 18 Ethernet Cables 18 100BASE T X Pin Assignments 18 SFP 20 Console Port Cable 20 WEB Management 22 Configuration by Web Browser 22 About Web...

Page 3: ...ing 27 PTP Client 29 LLDP 29 Auto Provision 30 Backup Restore 31 Upgrade Firmware 31 Redundancy 32 C Ring 32 Legacy Ring 34 COM Ring 35 C RSTP 36 RSTP 37 RSTP setting 37 MSTP 40 Multicast 44 Static Multicast Filtering 45 Port Setting 46 Port Control 46 Port Status 47 Rate Limit 47 Port Trunk 48 Port Trunk Setting 48 Port Trunk Status 49 VLAN 49 VLAN Setting IEEE 802 1Q 49 Traffic Prioritization 51...

Page 4: ...1 Static MAC Forwarding 62 MAC Blacklist 63 802 1x 64 802 1x Radius Server 64 802 1x Port Authorized Mode 66 802 1x Port Authorized Mode 67 TACACS 67 Warning 68 Monitor and Diag 71 System Event Log 71 MAC Address Table 72 Port Overview 73 Port Monitoring 74 Power over Ethernet PoE 75 System setting 75 Power over Ethernet Port Control 76 Port Status 77 Save Configuration 78 Factory Default 78 Syste...

Page 5: ...et List Spanning Tree command set 90 Commands Set List QoS command set 91 Commands Set List IGMP command set 92 Commands Set List MAC Filter Table command set 93 Commands Set List SNMP command set 94 Commands Set List Port Mirroring command set 95 Commands Set List 802 1x command set 96 Commands Set List TFTP command set 97 Commands Set List SYSLOG SMTP EVENT command set 97 Commands Set List SNTP ...

Page 6: ...fications or repairs done by persons other than ComNet approved personnel and this warranty does not apply to ComNet products that are misused abused improperly installed or damaged by accidents Please refer to the Technical Specifications section for the actual warranty period s of the product s associated with this publication Disclaimer Information in this publication is intended to be accurate...

Page 7: ...rnet a system to transmit electrical power with data to remote devices over standard twisted pair cable CNGE2FE8MSPOE2 has 8 X 10 100BASE T X PSE Power Sourcing Equipment ports that are fully compliant with IEEE802 3af standard WEB based TELNET Console port or other third party SNMP software can manage the CNGE2FE8MSPOE2 as well The switch can be managed by a useful utility called eConsole eConsol...

Page 8: ...notification by Email SNMP trap and Relay Output Web based Telnet Console CLI configuration Enable disable ports MAC based port security Port based network access control 802 1x VLAN 802 1Q to segregate and secure network traffic Radius centralized password management SNMPv3 encrypted authentication and access security RSTP 802 1w Quality of Service 802 1p for real time traffic VLAN 802 1Q with do...

Page 9: ... 95 non condensing Casing Aluminum 10 100BASE T X Ethernet port 10 100 1000BASE T X Gigabit Ethernet port combo 100 1000BASE X on SFP port combo Console Port Dimensions W D H 74 3mm 109 2mm 153 6mm Safety Indications Only ComNet service personnel can service the equipment Please contact ComNet Technical Support if your unit requires service The equipment should be installed in locations with contr...

Page 10: ...N MANUAL CNGE2FE8MSPOE2 TECH SUPPORT 1 888 678 9427 Hardware Installation Installing Switch on DIN Rail Each switch has a Din Rail kit on the rear panel The DIN Rail kit affixes the switch to the DIN Rail It is easy to install the switch on the Din Rail Metal Spring ...

Page 11: ...TALLATION AND OPERATION MANUAL CNGE2FE8MSPOE2 TECH SUPPORT 1 888 678 9427 Mount Series on DIN Rail Step 1 Tilt the switch and mount the metal spring to DIN Rail Step 2 Push the switch toward the DIN Rail until you hear the spring snap into place ...

Page 12: ...wall mount kit can be found in the package The following steps show how to mount the switch on the wall Mounting the CNGE2FE8MSPOE2 on a Wall Step 1 Remove Din Rail kit if it is attached to the switch Step 2 Use the 6 included screws to attach the wall mount panel as shown in the diagram below In order to prevent switches from being damaged use only the screws included with the mounting kit for th...

Page 13: ...iption 10 100 RJ 45 fast Ethernet ports 8 10 100BASE T X RJ 45 fast Ethernet ports support auto negotiation Default Setting Speed auto Duplex auto Flow control disable Gigabit RJ 45 ports 2 10 100 1000BASE T X Gigabit ports combo ports SFP ports 2 100 1000BASE X on SFP port combo PoE Ports Port 1 8 contain PSE function compliant with IEEE802 3af PoE specifications Console Use RS 232 to RJ 45 conne...

Page 14: ...LED will be light on 4 LED for R M Ring master When the LED light is on this switch is the C Ring ring master 5 LED for Ring When the LED light on it means the C Ring is activated 6 LED for Fault Relay When the fault occurs the amber LED will be light on 7 Console port RJ 45 8 LED for PoE power supplied 9 10 100BASE T X PSE Ethernet ports 10 LED for Ethernet ports speed 11 LED for Ethernet ports l...

Page 15: ...C Ring Master Ring Green On C Ring enabled Slowly blinking C Ring topology has fault Fast blinking C Ring works normally Fault Amber On Fault relay Power failure or Port down fail 10 100BASE T X Fast Ethernet ports LNK ACT Green On Port link up Blinking Data transmitted Full Duplex Amber On Port works under full duplex Gigabit Ethernet ports ACT Green On Port link up Blinking Data transmitted LNK ...

Page 16: ...SPOE2_REV 12 20 12 PAGE 16 INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE2 TECH SUPPORT 1 888 678 9427 Top view Panel The bottom panel components of CNGE2FE8MSPOE2 are shown as below 1 Terminal block 2 Ground wire ...

Page 17: ... 12 20 12 PAGE 17 INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE2 TECH SUPPORT 1 888 678 9427 Rear Panel The components in the rear of CNGE2FE8MSPOE2 are shown as below 1 Screw holes for wall mount kit 2 DIN Rail kit 1 1 2 ...

Page 18: ...ng table for cable specifications Cable Type Max Length Connector 10BASE T CAT3 CAT4 CAT5 100Ω UTP 100m 328ft RJ 45 100BASE TX CAT5 100Ω UTP UTP 100m 328ft RJ 45 1000BASE TX CAT5 CAT5 e 100Ω UTP UTP 100m 328ft RJ 45 Cable Types and Specifications 100BASE T X Pin Assignments With 100BASE T X cable pins 1 and 2 are used for transmitting data and pins 3 and 6 are used for receiving data Pin Number As...

Page 19: ...le below shows the 10BASE T 100BASE TX MDI and MDI X port pin outs Pin Number MDI port MDI X port 1 TD transmit RD receive 2 TD transmit RD receive 3 RD receive TD transmit 4 Not used Not used 5 Not used Not used 6 RD receive TD transmit 7 Not used Not used 8 Not used Not used 10 100 BASE TX MDI MDI X pins assignment Pin Number MDI port MDI X port 1 BI_DA BI_DB 2 BI_DA BI_DB 3 BI_DB BI_DA 4 BI_DC ...

Page 20: ...at the TX port of Switch A should be connected to the RX port of Switch B Switch A Switch B Console Port Cable CNGE2FE8MSPOE2 switches can be managed by the console port The DB 9 to RJ 45 cable can be found in the package You can connect them to the PC via a RS 232 cable with DB 9 female connector and the other end RJ 45 connector connects to console port of switch PC pin out male assignment RS 23...

Page 21: ...itted from DCE Device 3 Transmitted Data Transmitted from DTE Device Received Data Received by DCE Device 4 DTE Ready Transmitted from DTE Device DTE Ready Received by DCE Device 5 Signal Ground Signal Ground 6 DCE Ready Received by DTE Device DCE Ready Transmitted from DCE Device 7 Request to Send Transmitted from DTE Device Clear to Send Received by DCE Device 8 Clear to Send Received by DTE Dev...

Page 22: ...eb site resides in the flash memory on the CPU board It contains advanced management features and allows you to manage the switch from anywhere on the network through a standard web browser such as Microsoft Internet Explorer The Web Based Management function supports Internet Explorer 5 0 or later It is based on Java Applets with an aim to reduce network bandwidth consumption enhance access speed...

Page 23: ...1 Subnet Mask 255 255 255 0 Default Gateway 192 168 10 254 User Name admin Password admin System Login 1 Launch Internet Explorer 2 Type http 192 168 10 1 and the IP address of the switch Press Enter 3 The login screen appears 4 Enter username and password The default username and password is admin 5 Select Enter or OK button then the main interface of the Web based management appears Login screen...

Page 24: ...m Information System Information interface System Information The system information will display the configuration of Basic Setting Switch Setting page Enable Location Alert Select Enable Location Alert and observe that the PWR1 PWR2 and FAULT LEDs of the switch will start to flash together Select Disable Location Alert and the LEDs will stop flashing ...

Page 25: ... switch System Location Assign the switch physical location The maximum length is 64 bytes System Contact Enter the name of contact person or organization Admin Password This page allows you to configure the system password required to access the web pages Admin Password interface Label Description User name Key in the new username The default is admin New Password Key in the new password The defa...

Page 26: ... dialog shows up to inform when the DHCP client is enabling The current IP will lose and you should find a new IP on the DHCP server IP Address Assign the IP address that the network is using If the DHCP client function is enabled you do not need to assign the IP address The network DHCP server will assign the IP address for the switch and it will be display in this column The default IP is 192 16...

Page 27: ...Enable or disable daylight saving time function When daylight saving time is enabling you need to configure the daylight saving time period UTC Time zone Set the switch location time zone The following table lists the different location time zone for your reference Label Description Daylight Saving Time Disable or Enable DST Time Adjustment Daylight Saving Period Set up the Daylight Saving beginni...

Page 28: ...rd ADT Alaskan Daylight 8 hours 4 am ALA Alaskan Standard 9 hours 3 am HAW Hawaiian Standard 10 hours 2 am Nome Alaska 11 hours 1 am CET Central European FWT French Winter MET Middle European MEWT Middle European Winter SWT Swedish Winter 1 hour 1 pm EET Eastern European USSR Zone 1 2 hours 2 pm BT Baghdad USSR Zone 2 3 hours 3 pm ZP4 USSR Zone 3 4 hours 4 pm ZP5 USSR Zone 4 5 hours 5 pm ZP6 USSR ...

Page 29: ...ge can be achieved with this protocol when using hardware generated timestamps Label Description PTP Client Enable Disable PTP Client LLDP LLDP Link Layer Discovery Protocol function allows the switch to advertise its information to other nodes on the network and store the information it discovers LLDP configuration interface Label Description LLDP Protocol Enable or Disable LLDP function LLDP Int...

Page 30: ...o Provision allows you to automatically update the switch firmware You can put the firmware or configuration file on TFTP server When you reboot the switch it will upgrade automatically Before updating make sure you have your TFTP server ready and the firmware image and configuration file is on the TFTP server Auto Provision interface ...

Page 31: ... File Name Fill the file name Restore Select Restore to restore the configurations Form Local PC User can select file restore not need TFTP server Restore File Name Fill in the file name Restore Select Restore to restore the configurations Backup Select Backup to backup the configurations To Local PC User can download config file to switch Not needing the TFTP server Upgrade Firmware Upgrade Firmw...

Page 32: ...H SUPPORT 1 888 678 9427 Redundancy C Ring C Ring is the most powerful Redundant Ring in the world The recovery time is less than 10ms It can reduce unexpected damage caused by a network topology change C Ring supports three Ring topologies C Ring Coupling Ring and Dual Homing C Ring interface ...

Page 33: ...all switches when network topology changes It is a good application for connecting two Rings Coupling Port Link to Coupling Port of the switch in another ring Coupling Ring need four switch to build an active and a backup link Set a port as coupling port The coupled four ports of four switches will be run at active backup mode Control Port Link to Control Port of the switch in the same ring Contro...

Page 34: ...cover from the failure The switch supports the function and interface for setting the switch as the ring master or not The ring master can negotiate and place command to other switches in the X Ring group If there are 2 or more switches in master mode the software will select the switch with lowest MAC address number as the ring master The X Ring master ring mode can be enabled by setting the Lega...

Page 35: ...th another vendor s managed switch ComRing interface Label Description Enable Enable the COM Ring function Vendor Select the vendor whose ring you want to join 1st Ring Port Select the port that connects to the ring 2nd Ring Port Select the port that connects to the ring The application of COM Ring is shown as below ComNet Switch ComNet Switch Other Vendor s Switch Other Vendor s Switch Other Vend...

Page 36: ...ing technology invented by ComNet Different from standard STP RSTP the recovery time of C RSTP is 10ms and supports more nodes of connection in a ring topology C RSTP interface The application of C RSTP is shown as below CNGE2FE8MSPOE2 CNGE2FE8MSPOE2 CNGE2FE8MSPOE2 IPC PLC CNGE2FE8MSPOE2 CNGE2FE8MSPOE2 Server CNGE2FE8MSPOE2 CNGE2FE8MSPOE2 C RSTP connection ...

Page 37: ... value has the highest priority and is selected as the root If the value changes You must restart the switch The value must be a multiple of 4096 according to the protocol standard rule Max Age Time 6 40 The number of seconds a bridge waits without receiving Spanning tree Protocol configuration messages before attempting a reconfiguration Enter a value from 6 through 40 Hello Time 1 10 The time th...

Page 38: ...INS_CNGE2FE8MSPOE2_REV 12 20 12 PAGE 38 INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE2 TECH SUPPORT 1 888 678 9427 View the RSTP algorithm results at this table ...

Page 39: ...ther the port concerned can only be connected to exactly one other bridge i e It is served by a point to point LAN segment or it can be connected to two or more bridges i e It is served by a shared medium LAN segment This function allows the P2P status of the link to be manipulated administratively True means P2P enabling False means P2P disabling Admin Edge The port directly connected to end stat...

Page 40: ...ee Protocol MSTP is a standard protocol base on IEEE 802 1s The function is that several VLANs can be mapped to a reduced number of spanning tree instances because most networks do not need more than a few logical topologies It supports load balancing schemes and the CPU is sparer than PVST Cisco proprietary technology MSTP Setting interface ...

Page 41: ... according to the protocol standard rule Max Age Time 6 40 Time in seconds a bridge will wait to receive Spanning tree Protocol configuration messages before attempting a reconfiguration Enter a value 6 through 40 Hello Time 1 10 Follow the rule below to configure the MAX Age Hello Time and Forward Delay Time a controlled switch sends out the BPDU packet to check RSTP current status Enter a value ...

Page 42: ...ng bridge at the specified port Enter a number 1 through 200000000 Admin P2P Some of the rapid state transactions that are possible within RSTP are dependent upon whether the port in question can only be connected to exactly one other bridge i e It is served by a point to point LAN segment or whether it can be connected to two or more bridges i e It is served by a shared medium LAN segment This fu...

Page 43: ... If the value changes You must reboot the switch The value must be a multiple of 4096 according to the protocol standard rule Apply Select Apply to activate the configurations MSTP Instance Port interface Label Description Instance Set the instance s information except CIST Port Select the port that you want to configure Priority 0 240 Decide that port should be blocked by priority in LAN Enter a ...

Page 44: ...that carry multicast traffic It provides the ability to prune multicast traffic so that it travels only to those end destinations that require that traffic and reduces the amount of traffic on the Ethernet LAN IGMP Snooping interface Label Description IGMP Snooping Table Show current IP multicast list IGMP Protocol Enable Disable IGMP snooping IGMP Query Set switch IGMP querier status There should...

Page 45: ...ps With multicast filtering network devices only forward multicast traffic to the ports that are connected to registered end stations Multicast Filtering Interface Label Description IP Address Assign a multicast group IP address within the range of 224 0 0 0 through 239 255 255 255 Member Ports Select port numbers to include them as the member ports in the specific multicast group IP address Add S...

Page 46: ...e the port Speed Duplex Set Auto negotiation 100 full 100 half 10 full or 10 half mode Flow Control Support symmetric and asymmetric mode to avoid packet loss when congestion occurred Security Enabling port security will disable MAC address learning in this port Only the frames with MAC addresses in the port security list will be forwarded otherwise the frames will be discarded Auto Detect 100 100...

Page 47: ... multicast and flooded unicast You can also set Ingress or Egress to limit traffic received or transmitted bandwidth Rate Limit interface Label Description Ingress Limit Frame Type Set the mode of the Ingress port from All Broadcast Only Broadcast Multicast or Broadcast Multicast Flooded Unicast Ingress The switch port received traffic For no limit set to zero 0 Egress The switch port transmitted ...

Page 48: ...g interface Label Description Group ID Select port to join a trunk group Type Support static trunk and 802 3ad LACP Work Port Select the number of active ports in dynamic group LACP The default value of works ports is maximum number of the group If the number is not maximum number of ports the other inactive ports in dynamic group will be suspended no traffic Once the active port is broken the sus...

Page 49: ...ed and 802 1Q tagged based VLAN The default configuration of VLAN operation mode is 802 1Q VLAN Setting IEEE 802 1Q Tagged based VLAN is an IEEE 802 1Q specification standard and it is possible to create a VLAN across devices from different switch vendors IEEE 802 1Q VLAN uses a technique to insert a tag into the Ethernet frames The Tag contains a VLAN Identifier VID that indicates the VLAN number...

Page 50: ...ort Select the port to configure Link type Select Link Type from the following options Access Link Single switch only allows grouping of ports by setting the same VID Trunk Link Extended application of Access Link allows grouping of ports by setting the same VID with 2 or more switches Hybrid Link Both Access Link and Trunk Link are available Hybrid QinQ Link Allows one more VLAN tag in a original...

Page 51: ... the output priority is determined by COS only TOS only the output priority is determined by TOS only COS first the output priority is determined by COS and TOS but COS first TOS first the output priority is determined by COS and TOS but TOS first QOS policy Using the 8 4 2 1 weight fair queue scheme the output queues will follow 8 4 2 1 ratio to transmit packets from the highest to lowest queue F...

Page 52: ...RATION MANUAL CNGE2FE8MSPOE2 TECH SUPPORT 1 888 678 9427 Port base priority Port based Priority interface Priority Assign Port with one of four available priority queues High Middle Low and Lowest Apply Select Apply to set the configurations Help Show help file ...

Page 53: ... 1p It describes that the output priority of a packet is determined by the user priority field in 802 1Q VLAN tag The priority value is supported 0to7 COS value map to 4 priority queues High Middle Low and Lowest COS Port Default When an ingress packet has no VLAN tag a default priority value is considered and determined by ingress port Apply Select Apply to set the configurations Help Show help f...

Page 54: ... a field in the IP header of a packet This TOS field is also used by Differentiated Services and is called the Differentiated Services Code Point DSCP This field can determine the output priority of a packet and the priority value is supported 0to63 DSCP value map to 4 priority queues High Middle Low and Lowest Apply Select Apply to set the configurations Help Show help file ...

Page 55: ...s is the beginning of the dynamic IP assignments range For example dynamic IP assignment range is from 192 168 1 100 to 192 168 1 200 192 168 1 100 will be the Start IP address End IP Address The dynamic IP assignment range High IP address is the end of the dynamic IP assignments range For example dynamic IP assignment range is from 192 168 1 100 to 192 168 1 200 192 168 1 200 will be the End IP a...

Page 56: ...P client information and display in here DHCP Server Client Entries interface DHCP Server Port and IP bindings You can assign the specific IP address that is in the assigned dynamic IP range to the specific port When the device connects to the port and asks for dynamic IP assigning the system will assign the IP address that has been assigned before in the connected device DHCP Server Port and IP B...

Page 57: ...hen forwarding server DHCP packets to a DHCP client Label Description DHCP Relay Enable Disable DHCP Relay Agent DHCP Server IP Address and VID Specify the IP address and VID of DHCP server 0 0 0 0 means server is inactive DHCP Option 82 Remote ID Option 82 Remote ID provides an identifier for the remote server There are 4 types supported IP MAC Client ID and Other DHCP Option 82 Circuit ID Table ...

Page 58: ... related information by Agent Setting Function SNMP Agent setting interface Label Description SNMP agent Version Three SNMP versions are supported such as SNMP V1 SNMP V2c and SNMP V3 SNMP V1 SNMP V2c agent uses a community string match for authentication that means SNMP servers access objects with read only or read write permissions with the community default string public private SNMP V3 require...

Page 59: ...ign the user name that you have set up in user table Group Name set up the group name Select Add to add context name Select Remove to remove unwanted context name Access Table Configure SNMP v3 access table Context Prefix set up the context name Group Name set up the group Security Level select the access level Context Match Rule select the context match rule Read View Name set up the read view Wr...

Page 60: ...ill be issued Create a trap manager by entering the IP address of the station and a community string To define management stations as a trap manager and enter SNMP community strings and select the SNMP version SNMP Trap Setting interface Label Description Server IP The server IP address to receive Trap Community Community for authentication Trap Version Trap Version supports V1 and V2c and V3 Add ...

Page 61: ...t Security Only IP in the Secure IP List can manage the switch through your defined management mode WEB Telnet SNMP IP Security interface Label Description IP security MODE Enable Disable the IP security function Enable WEB Management Mark the blank to enable WEB Management Enable Telnet Management Mark the blank to enable Telnet Management Enable SNMP Management Mark the blank to enable MPSN Mana...

Page 62: ...sses to hardware forwarding database If port security is enabled at Port Control page only the frames with MAC addresses in this list will be forwarded otherwise will be discarded Port Security interface Label Description MAC Address Input MAC Address to a specific port Port NO Select port of switch Add Add an entry of MAC and port information Delete Delete the entry Help Show help file ...

Page 63: ...forwarding to specific MAC addresses in list Any frames forwarding to MAC addresses in this list will be discarded Thus the target device will never receive any frame MAC Blacklist interface Label Description MAC Address Input MAC Address to add to MAC Blacklist Port NO Select port of switch Add Add an entry to Blacklist table Delete Delete the entry Help Show help file ...

Page 64: ...or Disable 802 1X Radius Server function Radius Server IP The IP address of the authentication server Server port Set the UDP port number used by the authentication server to authenticate Account port Set the UDP destination port for accounting requests to the specified Radius Server Shared Key A key shared between this switch and authentication server NAS Identifier A string used to identify this...

Page 65: ...cant response to an EAP request Server Timeout Set the period of time the switch waits for a Radius server response to an authentication request Max Requests Set the maximum number of times to retry sending packets to the supplicant Re Auth Period Set the period of time after that clients connected must be re authenticated Apply Select Apply to set the configurations Help Show help file ...

Page 66: ...de of each port 802 1x Port Authorize interface Label Description Port Authorized Mode Reject force this port to be unauthorized Accept force this port to be authorized Authorize the state of this port was determined by the outcome of the 802 1x authentication Disable this port will not participate in 802 1x Apply Select Apply to set the configurations Help Show help file ...

Page 67: ...8MSPOE2_REV 12 20 12 PAGE 67 INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE2 TECH SUPPORT 1 888 678 9427 802 1x Port Authorized Mode Show 802 1x port authorized state 802 1x Port Authorize State interface TACACS ...

Page 68: ...u can monitor the switch through selected system events Warning Fault Relay Alarm When any selected fault event happens the Fault LED in switch panel will light and the electric relay will signal at the same time System Warning SYSLOG Setting The SYSLOG is a protocol to transmit event notification messages across networks Please refer to RFC 3164 The BSD SYSLOG Protocol System Warning SYSLOG Setti...

Page 69: ...g interface Label Description E mail Alart Enable Disable transmission system warning events by Email SMTP Server IP Address Setting up the mail server IP address Mail Subject The subject line of the Email Sender Set up the Email account from which to send the alert Authentication Username the authentication username Password the authentication password Confirm Password re enter password Recipient...

Page 70: ...ckbox cannot be checked when SYSLOG or SMTP is disabled System Warning Event Selection interface Label Description Device cold start When the device executes cold start the system will issue a log event Device warm start When the device executes warm start the system will issue a log event Authentication Failure Alert when SNMP authentication failure ComRing topology change Alert when ComRing topo...

Page 71: ...UPPORT 1 888 678 9427 Monitor and Diag System Event Log If system log client is enabled the system event logs will be shown in this table System event log interface Label Description Page Select LOG page Reload To get the newest event logs and refresh this page Clear Clear log Help Show help file ...

Page 72: ...nation MAC address is to be forwarded through a given potential transmission port MAC Address Table interface Label Description Port NO Show all MAC addresses mapping to a selected port in table Flush MAC Table Clear all MAC addresses in table MAC Address Aging Time Assign aging time MUST be multiple of 15 Auto Flush Table When Ports Link Down Enable this function when port link down the switch wi...

Page 73: ...k Show port link status State Show ports enable or disable TX GOOD Packet The number of good packets sent by this port TX Bad Packet The number of bad packets sent by this port RX GOOD Packet The number of good packets received by this port RX Bad Packet The number of bad packets received by this port TX Abort Packet The number of packets aborted by this port Packet Collision The number of times a...

Page 74: ...ce ports out to a selected RX destination port as well as sending the frame where it normally would have gone Keep all source ports unchecked in order to disable port monitoring Port monitoring interface Label Description Destination Port The port will receive a copied frame from the source port for monitoring purposes Source Port The port will be monitored Mark the blank of TX or RX to be monitor...

Page 75: ...here are 8 ports port 1 to port 8 act as PSE Power Supply Equipment ports Label Description Maximum Power Available Display the maximum power available Actual Power Consumption Display the actual power consumption Port Knockoff Disabled Check the Box to disable Port Knockoff AC Disconnect Check the Box to enable Disconnect AC function Capacitive Detection Check the Box to enable Capacitive Detecti...

Page 76: ...ark the checkbox to enable PoE function for specific ports Power Limit From Classification Set the Power Limit From Classification function for each PoE port Legacy The legacy detection is to identify the PD devices that did not follow the IEEE 802 3af standard their unique electrical signatures in order for the P O E switch can provide the power to those PD devices Priority Set port priority for ...

Page 77: ...us This screen shows detailed PoE status for each Port Label Description Port Port number State Show PSE Status Current mA Displays current value Voltage V Displays voltage value Power mW Displays watt value Determined Class Displays the power class If the Bypass classification is enabled the class value will not show in here ...

Page 78: ...tion will be lost when power is turned off or the system is reset System Configuration interface Label Description Save Save all configurations Help Show help file Factory Default Factory Default interface Reset switch to default configuration Select Reset to reset all configurations to the default value You can select Keep current IP address setting and Keep current username password to retain cu...

Page 79: ...management You can use console or telnet to management switch by CLI CLI Management by RS 232 Serial Console 9600 8 none 1 none Before Configuring by the RS 232 serial console use an RJ45 to DB9 F cable to connect the Switch s RS 232 Console port to your PCs COM port Follow the steps below to access the console via RS 232 serial cable Step 1 From the Windows desktop select on Start Programs Access...

Page 80: ...INS_CNGE2FE8MSPOE2_REV 12 20 12 PAGE 80 INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE2 TECH SUPPORT 1 888 678 9427 Step 2 Input a name for new connection Step 3 Select to use COM port number ...

Page 81: ...888 678 9427 Step 4 The COM port properties setting 9600 for Bits per second 8 for Data bits None for Parity 1 for Stop bits and none for Flow control Step 5 The Console login screen will appear Use the keyboard to enter the Username and Password same as for accessing via Web Browser and then press Enter ...

Page 82: ...ow IP Address 192 168 10 1 Subnet Mask 255 255 255 0 Default Gateway 192 168 10 254 User Name admin Password admin Follow the steps below to access the console via Telnet Step 1 Telnet to the IP address of the switch from the Windows Run command or from the MS DOS prompt Step 2 The Login screen will appear Use the keyboard to enter the Username and Password same as for accessing via Web Browser an...

Page 83: ...de Privileged this mode to Display advance function status save configures Global configuration Enter the configure command while in privileged EXEC mode switch config To exit to privileged EXEC mode enter exit or end Use this mode to configure parameters that apply to your Switch as a whole VLAN database Enter the vlan database command while in privileged EXEC mode switch vlan To exit to user EXE...

Page 84: ...escription System Description G Set switch system description string switch config system description xxx system contact System Contact G Set switch system contact window string switch config system contact xxx show system info E Show system information switch show system info ip address Ip address Subnet mask Gateway G Configure the IP address of switch switch config ip address 192 168 1 1 255 25...

Page 85: ...IP for DHCP clients by port switch config interface fastEthernet 2 switch config if dhcpserver ipbinding 192 168 1 1 show dhcpserver configuration P Show configuration of DHCP server switch show dhcpserver configuration show dhcpserver clients P Show client entries of DHCP server switch show dhcpserver clinets show dhcpserver ip binding P Show IP Binding information of DHCP server switch show dhcp...

Page 86: ...e I Enable security of interface switch config interface fastEthernet 2 switch config if security enable no security I Disable security of interface switch config interface fastEthernet 2 switch config if no security bandwidth type all I Set interface ingress limit frame type to accept all frame switch config interface fastEthernet 2 switch config if bandwidth type all bandwidth type broadcast mul...

Page 87: ... to specify the state mode of operation for Ethernet ports Use the disable form of this command to disable the port switch config interface fastEthernet 2 switch config if state Disable show interface configuration I show interface configuration status switch config interface fastEthernet 2 switch config if show interface configuration show interface status I show interface actual status switch co...

Page 88: ...omma ex 2 3 6 Workport The amount of work ports this value could not be less than zero or be large than the amount of member ports switch config aggregator group 1 1 4 lacp workp 2 or switch config aggregator group 2 1 4 3 lacp workp 3 aggregator group GroupID Port list nolacp G Assign a static trunk group GroupID 1to3 Port list Member port list This parameter could be a port range ex 1 4 or a por...

Page 89: ...k tag 2 3 6 99 or switch vlan vlan 8021q port 3 trunk link tag 3 20 vlan 8021q port PortNumber hybrid link untag UntaggedVID tag TaggedVID List V Assign a hybrid link for VLAN by port if the port belong to a trunk group this command can t be applied switch vlan vlan 8021q port 3 hybrid link untag 4 tag 3 6 8 or switch vlan vlan 8021q port 3 hybrid link untag 5 tag 6 8 vlan 8021q aggreator TrunkID ...

Page 90: ...nd to specify the interval between hello bridge protocol data units BPDUs switch config spanning tree hello time 3 spanning tree forward time seconds G Use the spanning tree forward time global configuration command to set the forwarding time for the specified spanning tree instances The forwarding time determines how long each of the listening and learning states last before the port begins forwa...

Page 91: ...anning tree no spanning tree G Disable spanning tree switch config no spanning tree Commands Set List QoS command set Commands Level Description Example qos policy weighted fair strict G Select QOS policy scheduling switch config qos policy weighted fair qos prioritytype port based cos only tos only cos first tos first G Setting of QOS priority type switch config qos prioritytype qos priority port...

Page 92: ... query auto G Set IGMP query to auto mode switch config Igmp query auto Igmp query force G Set IGMP query to force mode switch config Igmp query force show igmp configuration P Displays the details of an IGMP configuration switch show igmp configuration show igmp multi P Displays the details of an IGMP snooping entries switch show igmp multi no igmp G Disable IGMP snooping function switch config n...

Page 93: ... mac address table P Show all MAC address table switch show mac address table show mac address table static P Show static MAC address table switch show mac address table static show mac address table filter P Show filter MAC address table switch show mac address table filter no mac address table static hwaddr MAC I Remove an entry of MAC address table of interface static switch config interface fa...

Page 94: ...y strings public right RO or switch config snmp community strings public right RW snmp snmpv3 user User Name password Authentication Password Privacy Password G Configure the user profile for SNMPV3 agent Privacy password could be empty switch config snmp snmpv3 user test01 password AuthPW PrivPW show snmp P Show SNMP configuration switch show snmp show snmp server P Show specified trap server inf...

Page 95: ...t TX destination port of monitor function switch config monitor tx show monitor P Show port monitor information switch show monitor monitor RX TX Both I Configure source port of monitor function switch config interface fastEthernet 2 switch config if monitor RX show monitor I Show port monitor information switch config interface fastEthernet 2 switch config if show monitor no monitor I Disable sou...

Page 96: ...witch config 8021x system sharekey 123456 8021x system nasid words G Use the 802 1x system nasid global configuration command to change the NAS ID switch config 8021x system nasid test1 8021x misc quietperiod sec G Use the 802 1x misc quiet period global configuration command to specify the quiet period value of the switch switch config 8021x misc quietperiod 10 8021x misc txperiod sec G Use the 8...

Page 97: ... and the file name of image switch config restore flash restore_cfg upgrade flash upgrade_ fw G Upgrade firmware by TFTP and need to specify the IP of TFTP server and the file name of image switch config upgrade lash upgrade_ fw Commands Set List SYSLOG SMTP EVENT command set Commands Level Description Example systemlog ip IP address G Set System log server IP address switch config systemlog ip 19...

Page 98: ...ange both event systemlog Link UP Link Down Both I Set port event for system log switch config interface fastethernet 3 switch config if event systemlog both event smtp Link UP Link Down Both I Set port event for SMTP switch config interface fastethernet 3 switch config if event smtp both show event P Show event selection switch show event no event device cold start G Disable cold start event type...

Page 99: ...config sntp daylight period 20060101 01 01 20060202 01 01 sntp daylight offset Minute G Set offset of daylight saving time if SNTP function is inactive this command can t be applied switch config sntp daylight offset 3 sntp ip IP G Set SNTP server IP if SNTP function is inactive this command can t be applied switch config sntp ip 192 169 1 1 sntp timezone Timezone G Set timezone index use show snt...

Page 100: ...d Ring Port G Configure 1st 2nd Ring Port switch config ring ringport 7 8 Ring couplingport Coupling Port G Configure Coupling Port switch config ring couplingport 1 Ring controlport Control Port G Configure Control Port switch config ring controlport 2 Ring homingport Dual Homing Port G Configure Dual Homing Port switch config ring homingport 3 show Ring P Show the information of C Ring switch sh...

Page 101: ...02 1p for COS Class of Service IEEE 802 1Q for VLAN Tagging IEEE 802 1w for RSTP Rapid Spanning Tree Protocol IEEE 802 1s for MSTP Multiple Spanning Tree Protocol IEEE 802 1x for Authentication IEEE 802 1AB for LLDP Link Layer Discovery Protocol IEEE802 3af PoE specification up to 15 4 Watts per port for PSE MAC Table 8192 MAC addresses Priority Queues 4 Processing Store and Forward Switch Propert...

Page 102: ... Include SMTP for event warning notification via email Event selection support RS232 Serial Console Port RS232 in RJ 45 connector with console cable 9600Bps 8 N 1 LED indicators Power PoE Indicator Green Power LED x 3 Green PoE LED x 8 C Ring Indicator Green Indicate system operated in C Ring mod R M indicator Green Indicate system operated in C Ring Master mode Fault indicator Amber Indicate unex...

Page 103: ...g Regulatory approvals EMI FCC Part 15 CISPR EN55022 class A EMS EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 CS EN61000 4 8 EN61000 4 11 Shock IEC60068 2 27 Free Fall IEC60068 2 32 Vibration IEC60068 2 6 Safety EN60950 1 Warranty Lifetime Note The PoE port may be considered SELV circuits if Not likely to require connection to an Ethernet network with outside plant ...

Page 104: ...INS_CNGE2FE8MSPOE2_REV 12 20 12 PAGE 104 INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE2 TECH SUPPORT 1 888 678 9427 ...

Page 105: ...ECH SUPPORT 1 888 678 9427 INFO COMNET NET 8 TURNBERRY PARK ROAD GILDERSOME MORLEY LEEDS UK LS27 7LE T 44 0 113 307 6400 F 44 0 113 253 7462 INFO EUROPE COMNET NET MECHANICAL INSTALLATION INSTRUCTIONS ComNet Customer Service Customer Care is ComNet Technology s global service center where our professional staff is ready to answer your questions at any time Email ComNet Global Service Center custom...

Reviews: