Proper use

The XN300 switch XN-332-5ETH-UMS is an integral part 

of the XN300 system. It can be used to connect multiple 

network segments with its five ports and have the data 

packets coming into one of five Ethernet ports (X1–X5)  

be distributed to the other ports.
Power supply and signal terminals must be protected 

against accidental contact and covered.
The XN300 system may only be operated if it has been 

correctly fitted and connected by qualified electrical 

specialists. The installation must comply with regulations for 

electromagnetic compatibility (EMC).

 

DANGER

COMMISSIONING THE XN300 SYSTEM DEVICES AND SWITCHING 

THEM ON MUST NOT RESULT IN ANY HAZARDS BEING POSED 

BY THE DEVICES BEING DRIVEN, E.G., UNEXPECTED MOTOR 

STARTUPS AND EQUIPMENT BECOMING UNEXPECTEDLY 

ENERGIZED.

Overview of functions

The XN-332-5ETH-UMS XN300 switch features the same 

design as the other devices in the XN300 system.
The aforementioned XN300 system includes XN300 slice 

modules in the form of I/O modules and speciality modules, 

as well as gateways such as the XN-312-GW-CAN and 

XN-312-GW-EC.
The XN-332-5ETH-UMS is an unmanaged switch without 

a system bus and is accordingly snapped onto the top hat 

DIN rail as a standalone device.

NOTICE

DO NOT ATTEMPT TO INSTALL THE XN-332-5ETH-UMS WITHIN AN 

XN300 SYSTEM BLOCK.

Power is provided via a 24 Vdc power input at the top  

of the device.

Versions

The XN300 switch is housed in a double-width case. Power 

is supplied from above through a 4-pin FMC 1.5/4-ST-3.5 

connector.

Figure 1 .  XN-332-5ETH-UMS front view

 

LED RN

 

LED DC

X1

 

LED LA

 

LED FD

 

ETH1

X2

 

XLED LA

 

LED FD

 

ETH2

X3

 

LED LA

 

LED FD

 

ETH3

X4

 

LED LA

 

LED FD

 

ETH4

X5

 

LED LA

 

LED FD

 

EHT5

X6

 

POW

RN
DC

LA

X1

FD

LA

X2

FD

LA

X3

FD

LA

X4

FD

LA

X5

FD

Summary of Contents for XN300

Page 1: ...Instruction manual XN300 switch XN 332 5ETH UMS...

Page 2: ...AR PURPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUMENT S...

Page 3: ...and abbreviations vi Writing conventions vi XN300 SWITCH XN 332 5ETH UMS 1 Proper use 1 Overview of functions 1 Versions 1 Ethernet connections 2 LED status indicators 2 Potential relationship betwee...

Page 4: ...ic tasks and procedures are located throughout the manual DANGER HAZARDOUS VOLTAGE CONTACT WITH HAZARDOUS VOLTAGE WILL CAUSE DEATH OR SEVERE PERSONAL INJURY FOLLOW ALL LOCALLY APPROVED SAFETY PROCEDUR...

Page 5: ...or wire breakage on the signal side will not result in undefined states in the automation devices Ensure a reliable electrical isolation of the low voltage for the 24 V supply only use power supply un...

Page 6: ...es The devices described here must only be set up and operated as specified in this manual and in the installation instructions provided with the device Installation commissioning operation maintenanc...

Page 7: ...E G UNEXPECTED MOTOR STARTUPS AND EQUIPMENT BECOMING UNEXPECTEDLY ENERGIZED Overview of functions The XN 332 5ETH UMS XN300 switch features the same design as the other devices in the XN300 system The...

Page 8: ...status indicators The device s status LEDs are located underneath the front cover and can be seen underneath the corresponding labels when they light up Table 1 LED meanings LED Color EtherCAT status...

Page 9: ...must be installed in a horizontal position module designation on top In order to ensure that the maximum operating ambient temperature will not be exceeded make sure that there is enough clearance bet...

Page 10: ...screwdriver to do this Figure 6 Locking the XN 332 5ETH UMS into place on the DIN rail Step 7 Check to make sure that the XN 332 5ETH UMS is solidly mounted Dismantling XN 332 5ETH UMS To remove the...

Page 11: ...ctor simply needs to be slid into the appropriate contact In order to release the conductor simply press on the release mechanism e g with a screwdriver to pull out the conductor from the correspondin...

Page 12: ...ecessary to make sure that a total current of 4 A is not exceeded per terminal External 24 Vdc voltages can also be distributed using an XN 322 4PS 20 power distribution module or XN 322 18PD P and XN...

Page 13: ...462 XN 312 XN 322 E135462 NA certification cULus Protection type IEC IP20 Dimensions All XN300 system devices have the exact same dimensions Description Specification Dimensions W x H x D mm 25 x 101...

Page 14: ...installed between the power supply and the end device Cable cross sections Cable cross sectional areas XN 332 0 39 inch 10 mm Solid mm2 0 2 1 5 0 39 inch 10 mm Flexible with uninsulated ferrule mm2 0...

Page 15: ...9 Instruction manual MN050011EN August 2022 www eaton com...

Page 16: ...rd Cleveland OH 44122 United States Eaton com 2022 Eaton All Rights Reserved Printed in USA Publication No MN050011EN Z26444 August 2022 Eaton is a registered trademark All trademarks are property of...

Reviews: