17
Interfaces
CTX15
data interface
Built-in module
Product description
The CTX15 is a universal serial data interface in a
module housing, that makes it possible to send and
receive Xanura signals from other equipment, such as an
alarm installation, micro processor or PLC via a
potential-free (and galvanically separated) serial
connection.
Characteristics
•
Galvanically separated input and output connectors:
- 1 potential-free input: RXD serial
- 1 potential-free output: TXD serial
•
Can send and receive all Xanura addresses
and commands
•
Baudrate 19200
•
ASCII-protocol
•
Internal message buffer
(max. 30 sec.)
•
On request: baudrate 9600, 60 Hz
•
On request: RS485 address option
Installation instructions
•
Phase and neutral wires must be fitted
•
Secondary supply circuit (+5 V) necessary
•
Can be applied as a transparent interface in
the function of an OEM module
Green
Yellow
Rad
Black
TXD
V+
CTX15
V+
5V d.c.
+
-
RXD
V+
TXD
RXD
Alarm installation
PLC
of
processor
N
L
230V
50Hz
SAX35
potential-free actuator/interface
Cable housing
Product description
The SAX35 is, just as the SAX15, a potential-free
actuator/interface, however it has a cable housing
for linking the signals of, for example, the doorbell,
electronic lock or heating system (24 V a.c.) to Xanura.
Characterisics
•
2 inputs and 1 output
(potential-free and separated galvanically)
•
Sends ON/OFF signals (Max. 2 addresses)
•
Receives ON/OFF signals and transposes these
after the relay has closed and then opened again.
(Max. 5 A, 30 V)
•
Can be included in a group command
•
Automatic status request is possible
•
Request for the status after commands
have been sent is possible.
•
Length of the primary supply cable is 1.5 m:
is provided with an euro plug
Operation
The input connectors and switching output
connectors operate independently of each
other. Send and receive addresses have to be
addressed separately. The module has two
linked send addresses and one receive address (relay).
Installation instructions
•
Phase and neutral wires must be fitted
•
Rated external supply (+5 V ___+ 24 V a.c. or
V d.c., for example bell voltage) needed for feeding
the input connectors maximum 7.5 mA
S2
S1
Address 2
Address1
Address 3
SAX35
+
+
5...24V a.c./d.c.
Max. 5A
30V a.c./d.c.
+
-
+
-
5...24V a.c./d.c.
CTX35
data interface
Cable housing
Product description
The CTX35 is, just as the CTX15, a universal serial data
interface, however it is mounted in a cable housing that
makes it possible to send and receive Xanura signals
from other apparatus (such as a PC, microprocessor or
PLC) via a potential-free and galvanically separated serial
connection.
Characteristics
•
Galvanic separated connection with PC by means of
9-pole Sub-D female RS232
- 1 potential-free input connector: RXD serial
- 1 potential-free output connector: TXD serial
•
With built-in transceiver RS232
•
Can send and receive all Xanura
addresses and commands
•
Baudrate 19200
•
ASC11 protocol
•
Internal message buffer of 30 seconds
•
On request, baudrate 9600, 60Hz can be supplied
•
On request, RS485 addressing possibilities
•
Length of cable for primary supply 1.5 m:
provided with euro plug
Installation instructions
•
Phase and neutral wires must be fitted
•
Can be connected to a PC or (internet) server
TXD
CTX35
RXD
RS232
1
2
3
4
5
6
7
8
9
9-pole SubD
Female
PC or server
COM-port