background image

Operation

10

Coupling of external appliances

Xanura is an open system. Any potential-free outlets 

of electrical appliances can be connected to the

potential-free wiring of the Xanura modules. In this

way, it is possible to let external appliances create

Xanura commands, for instance an existing alarm

system that activates the lighting when an emergency

situation occurs.

Single or three phase?

When installing the equipment, it is important to 

know whether an installation in the home has single 

or three phase wiring. If it concerns a three phase

installation and the Xanura components are divided

over more than one phase, then it is necessary to

install a phase coupler. This phase coupler is mounted

in the meter cupboard and sends the Xanaru

commands that have been received via one phase, 

on to the other phases. In addition, these signals 

are amplified for all three phases.

Suppression filter

To prevent the signals that are transmitted via the

lighting network from leaving the building, and possible

signals from outside from entering it, filters need to 

be fitted. This filtering can take place in the meter

cupboard by means of a suppression filter. This filter is

a modular component that can be mounted in the

distribution box.

No demolition or chasing work 

Xanura can be applied in both new and existing homes.

No demolition or chasing work is necessary. 

What are the minimum demands for 
applying Xanura?

To be able to install Xanura by using the built-in

modules that make it invisible, has to be taken the

depth of the built-in junction boxes into account. For

switches, a minimum depth of 40 mm is required.

Front and side view of built-in AIX module

The same applies for wall sockets that are not earthed.

For earthed wall sockets, built-in junction boxes with a

depth of 50 mm are required. Apart from the depth of

the junction boxes, the fact that phase and neutral

wiring has to be fitted also has to be taken into

consideration. This means that a neutral wire has to be

run through to the junction boxes where switches are

fitted. In brief, a newly built home provided with 50

mm junction boxes and phase and neutral wiring is

suitable for (future) installation of Xanura.

During what stage of the home being built should
Xanura be installed?

Xanura can be installed as soon as the above-

mentioned minimum installation demands have been

satisfied. This can even be done after the home has

been built and is being lived in, and the residents have

had time to determine their requirements with regards

to automation facilities. The equipment can also be

extended at any time.

Installation by a skilled electrical contractor

Xanura is an advanced home automation system that

should be installed by a specialist in this field. For this

purpose, Eaton Holec organises special training

courses for electrical contracting engineers.

Installation tools

To be able to install Xanura quickly and professionally, 

it is recommended that, apart from the normal tools

required, use is also made of the Xanura(PUX)

programming unit. This unit can send and receive

Xanura commands and show them in the display.

Furthermore, the strength of the signal and the

interference noise level are measured. In this way, it is

possible to test the lighting network before the system

is installed and to remove any interference by means

of a filter. The modules that have been fitted can also

be tested straight away. Finally, the complete system

can be tested before the home is handed over to the

resident.

Programming of built-in modules

Each module is provided with an address and, where

applicable, a functionality. This can be set in the

module by activating the programming position on the

module and sending the commands by means of the

Xanura(PUX) programming unit. Addresses can also be

provided by means of a computer interface(CIX). Once

the modules have been provided with an address, the

addresses cannot be removed, even if a power cut

occurs. Consequently, the modules can be provided

with an address in the workshop or on site. 

P

Adres

AIX

N N

Prog.

Summary of Contents for Xanura

Page 1: ...me automation Xanura home automation system Home automation for new and existing buildings Technical description Application examples Installation tips Functionalities Sales support Ordering informati...

Page 2: ...e modular concept 4 Functionalities Xanura 6 Operation 8 Product description 11 Switching actuators 11 Dimming actuators 12 Interfaces 13 RF components 19 Remaining components 20 Practical examples 22...

Page 3: ...ing work is not necessary and installation and material costs are therefore greatly reduced By fitting transmitting and receiving components behind switches and wall sockets so that they are invisible...

Page 4: ...witching Operation of the TV or audio with one universal remote control device ABX1 Lamps 3 and 4 can be dimmed or switched independently with the DIX2 and universal remote control device ABX1 Outside...

Page 5: ...vators GIX Group Interface Xanura Mounted behind switches or pulse switches For control of various activators by means of group commands AIX12 On Off Interface Xanura Mounted behind for example any 23...

Page 6: ...es or scenarios can be switched on or off with a mobile telephone by simply phoning into the Xanura system Which automatic switching operations are possible with Xanura Each light appliance provided w...

Page 7: ...intervals When something wrong occurs all the downstairs lights can be switched on from one switch in the bedroom When outdoor movement is detected the outdoor lighting is turned on and for instance 1...

Page 8: ...and switches without being visible Switching actuators Two types of switching actuator modules are available for application with Xanura i e one for mounting behind wall junction boxes and another fo...

Page 9: ...fferent lamps can be switched at various times Almost all switching operations that can be translated into conditions and actions IF THEN can be easily programmed in the computer interface with the Wi...

Page 10: ...taken into consideration This means that a neutral wire has to be run through to the junction boxes where switches are fitted In brief a newly built home provided with 50 mm junction boxes and phase...

Page 11: ...thed wall sockets a junction box of 50 mm is required Junction box Adres SAX1 Prog N N L Prog Adres SAX1 N N L SAX1 2 address is free for use switch pulse switch Adres SAIX Prog N N L nd P Adres SAIX...

Page 12: ...ching can be carried out in combination with dimmer interfaces Installation instructions Phase and neutral wiring must be fitted Junction box must be at least 40 mm deep Adres DAIX10 Prog Toggle pulse...

Page 13: ...must be at least 40 mm deep Interfaces To operate the switching dimming actuators that have been fitted interfaces are required When desired each switching actuator can be controlled by more than one...

Page 14: ...itches pulse switches can be connected to a GIX A maximum of 16 addresses can be controlled with one GIX by means of group commands Operation The wires of the GIX module can be connected to a potentia...

Page 15: ...X1 modules that operate air suction ventilators installed in homes These ventilators have three operating positions By applying several VIX10 interfaces it is possible to operate the three positions o...

Page 16: ...e CIX it is possible to store individual Xanura scenarios that can be carried out in a home provided with Xanura components The CIX electronic clock calendar makes it possible to carry out the scenari...

Page 17: ...tus request is possible Request for the status after commands have been sent is possible Length of the primary supply cable is 1 5 m is provided with an euro plug Operation The input connectors and sw...

Page 18: ...d Automatic status notification possible Request for the status after commands have been sent is possible Provided with 20 cm long wires Operation The input and output connectors work independently of...

Page 19: ...in the device Self programming for appliances that are not programmed Provides a number of standard group commands Range 30 metres in open space CAX RF Communication access interface Product descripti...

Page 20: ...se signals are then amplified to the maximum signal level and transmitted on all phases Installation instructions The phase coupler must be connected to a 16 A 3 phase circuit SFX40 suppression filter...

Page 21: ...amming unit Product description The PUX is an indispensible tool for the proficient installation of Xanura With this programming unit the Xanura modules can be easily programmed Furthermore Xanura com...

Page 22: ...e lights and TV video and audio appliances with only one remote control device When nobody is at home switching of the lights to give the impression that the home is occupied Varying daily sequences T...

Page 23: ...sily be changed software for other applications Due to the fact that the modules are fed by phase and neutral wires it is only necessary to fit a SAIX switch in the garden shed M Light m can thus be s...

Page 24: ...e protected electrical contractors section of www xanura nl In addition potential customers who ask Eaton Holec for more information can be referred to these contractors In this manner Eaton Holec inv...

Page 25: ...the CD ROM Live in your own home longer in which all the applications of Xanura that are related to the health care sector are explained CD ROM Easy living with Xanura To keep your customers informed...

Page 26: ...dule DIX2 1807 533 31726 0 Dim actuator built in module DAX10 1807 544 31553 2 Dim actuator dimmer interface built in module DAIX10 1807 543 32064 2 Group interface built in module GIX 1807 534 42126...

Page 27: ...Switching actuator 16 A modular SAX4 1807 520 53336 3 Sun blinds actuator ZAX 1807 537 53035 5 Movement detector RF BSX1 1807 506 42546 0 Suppression filter DIN modular component SFX40 1807 530 85312...

Page 28: ...vators GIX Group Interface Xanura Mounted behind switches or pulse switches For control of various activators by means of group commands AIX12 On Off Interface Xanura Mounted behind for example any 23...

Page 29: ...e SFX40 Basic package lighting and control 2 Type BPLX2 Eaton Holec No 1807 596 Reference No 531376 Contents Same as basic package lighting and control 1 with in addition 1 x Computer interface type C...

Reviews: