AXIS[ 1]
↑
QUIT
F1 QUIT to Previous Screen
POSITION AXIS
F2 Select Axis 1 or 2
ENG UNIT SAVE
F3 SAVE newly entered value to RAM memory
[1.0000 ]
↓
<EDT
F4 Select engineering unit type
AXIS[ 1]
↑
QUIT
F1 QUIT to Previous Screen
HOME AXIS
F2 Select Axis 1 or 2
DIRECTION SAVE
F3 SAVE newly entered value to RAM memory
[RETURN ]
↓
<SEL
F4
Selects RETURN or ADVANCE Direction
AXIS[ 1] (VAL)
↑
QUIT
F1 QUIT
FOR JOG SPEED AXIS
F2 Select 1 or 2
SELECT VARIABLE <VAR
F3
OR ENTER VALUE
↓
<VAL
F4
AXIS[ ]
↑
QUIT
F1 QUIT to Previous Screen
JOG SPEED IS AXIS
F2 Select 1 or 2
ASSIGNED TO SAVE
F3 SAVE to RAM
VARIABLE #C
↓
<EDT
F4 Enter Variable Number
AXIS[ 1]
↑
QUIT
F1 QUIT to Previous Screen
JOG SPEED AXIS
F2 Select 1 or 2
VALUE (IN/SEC) SAVE
F3 SAVE to RAM
[ ]
↓
<EDT
F4 Enter JOB Speed
FT = Foot
MM = Millimeter
RV = Revolution
CM = Centimeter
EU = Engineering Unit (counts)
Figure 3-6. Engineering Unit, Home Direction
and Job Speed Screens
19
Axis Parameter Screens
These screens are identical except for
the parameter name.
POSITION ENG UNIT
Position
feedback counts per measurement
length. (Depends on Transducer and
units used).
LOOP UPDATE RATE
Range .2 to 19
ms. This parameter can be useful when
tuning an axis for performance. The
Default Value is 0.200ms.
MAXIMUM POSITION
(EU)
MINIMUM POSITION
(EU)
MAXIMUM POSITION
ERROR
(EU)
IN POSITION ERROR
(EU)
MAXIMUM SPEED
(EU/SEC)
CREEP SPEED
(EU/SEC)
Error
recovery
speed
MAXIMUM
ACCELERATION
(EU/SEC^2)
MAXIMUM
DECELERATION
(EU/SEC^2)
D/A OFFSET
(D/A COUNTS)
HOME POSITION
(EU)
HOME OFFSET
(EU)
HOME SPEED
(EU/SEC)
For each above,
F1
Quit, Go to
previous
screen
F2
Axis, Selects
1 or 2
F3
Save, Saves
newly entered
value to RAM
Memory
F4
Brings up the
Parameter
screen
Push Enter.