51
Electrical System Interface
Electrical System
Interface
Eaton Installed Reverse Switch Electrical Requirements and Recommendations
•
Maximum incandescent DC lamp load current on 12 V nominal Vehicle Power: 4.2 A.
•
Maximum incandescent DC lamp load current on 24 V nominal Vehicle Power: 2.1 A.
•
Maximum resistive load current: 10 A.
•
Minimum wetting current: 200 ma.*
•
Wetting current must be provided at switch make.
•
Recommend use of no more than 2 typical incandescent lamps on a reverse switch. Additional lamps should be
controlled through a relay.
•
Multiple relays may be driven from a switch.
•
Multiple LED reverse lamps may be driven from a switch.
Note:
Some switches have extended limits.**
* Minimum whetting current is based on environmental temperature profile and how often the switch is actuated. The
value is a conservative estimate based on historical use of ball switches. Typically, less whetting current is required for
proper operation. Environmental validation is required to determine actual minimum whetting current.
** Contact your Eaton OEM Engineering Support Group for additional information.
Vehicle Electrical/Electronic System Component Recommendations
Relay Recommendations
•
Relays shall be sized for the application. This includes design considerations for wetting current and voltage across
contacts at closure.
•
Recommended Relays:
- Bosch: 0332-209-151 (+12 volt)
- Bosch: 0332-204-203 (+24 volt)
- Siemens: W28-15F24-S01 (+12 volt)