Electrical System Interface
Electrical System
Interface
Eaton Shift Lever
•
The OEM harness shift lever mating connector shall consist of the following connector systems:
-
The OEM harness Eaton Shift Lever mating connector system shall comprise of:
•
Deutsch P/N DTM06-08SA Connector Body
•
Deutsch P/N WM-8S Wedge-Lock
•
Deutsch gold plated Size 20 contacts for use with the DTM06-08SA connector body
•
Deutsch P/N 0413-204-2005 Filer Plug (optional for in-cab environments)
•
The insulation outside diameter of the connector shall comply with Deutsch requirements for the selected contact.
•
The OEM harness Eaton Shift Lever mating harness cable (wire) diameters shall be compliant with the following
insulation diameter requirements:
General Requirements
•
For connector systems that contain transmission signals or power sources, unused connectors shall have sealed
mating connectors connected to the unused connector or the unused connector shall be plugged with a sealed plug.
•
For connector systems that contain transmission signals or power sources, unused terminal cavities shall be plugged
with cavity plugs (filler plugs) for out of cab environments.
•
No anti-seize, lubricating, or foreign compound shall be applied to the connector jackscrew threads, including NyoGel
760G. Rational: The use of such compounds may affect jackscrew torque and prevent proper sealing of the connector.
•
Minimum wire gauge of 18 AWG shall be used for transmission signals except where mechanical reliability of 20 AWG
wire harnessing can be demonstrated.
•
All crimp contacts for connectors mating with Eaton components shall meet the supplier of the connector system's
crimp requirements.
•
For OEM harnesses that tie to transmission attachment points, tie wrap application and tightness shall conform to
Section 14.1.1 of IPC/WHMA-A-620 Requirements and Acceptance for Cable and Wire Harness Assemblies, January
2002 revision or later.
•
For OEM harnesses that tie to transmission attachment points, tie wrap application shall meet the Target and Defect of a
Class 3 product per IPC/WHMA-A-620.
•
All electrical power and signals referenced in italics shall be routed through an environmentally protected electrical
system to end point(s) of the signal.
Note:
The intent is that all signal connections are sealed where they may be exposed to water. Observation of proper
wire sizing and connector sealing practices should be followed.
Seal Range Diameter
(mm) / (in)
Contact Size
Description
TXL
1
AWG
GXL
1
AWG
SXL
1
AWG
1.35–3.04 / 0.053–0.120
20
Signal
16-20
16-20
18-20
1
Typical. Manufacturer’s insulation diameter should be confirmed to meet stated insulation diameter