Setting Options Menu
Page 45
Lock Set
Use this setting if you are using a lock to set the system.
To use
Lock Set
, you must:
Configure a Lock Set zone (see page 28) that is activated by a suitable lock
(located on the final exit door).
Configure a Final Exit zone (see page 26) connected to the final exit door.
Setting:
Once the user has started the setting sequence, the exit tone sounds, which
continues until the user closes the Final Exit door and operates the lock. When the
Settle Time
(page 45) expires, the control unit sets the system and converts the Final
Exit zone to a zone of type Normal Alarm.
Unsetting:
When a user de-activates the Lock Set zone, the control unit converts
any zone originally programmed as Final Exit back to Final Exit (so that the entry time
starts when the user opens the entry door) and starts a warning tone (distinct from
the entry tone). If the user activates the Lock Set zone again without starting the
Entry Timer, the control unit changes all Final Exit zones back into Normal Alarm
zones and stops the warning tone.
Note:
If you use
Lock Set
, you must set
After Entry
(page 53) to Never in order to
disable confirmation and comply with BS8243.
Exit Terminate
Setting:
The user must start the setting sequence in the normal way, and then
complete setting in one of the following ways once they have left the protected area:
a) By activating an Exit Terminate zone (see page 28).
b) By presenting a proximity reader tag to a KEY-EP external proximity reader
connected to a suitable keypad. This requires
System Options
– User Options – User
Access
– Terminated Set
to be set to Y (page 49).
When the user starts the setting sequence, the exit tone is sounded and the exit time
does not expire. Once the user completes the setting sequence, the system sets
when the
Settle Time
(page 45) expires.
The user can unset using any of the following methods:
a) By presenting a proximity tag to an external proximity tag reader.
c) By activating a Final Exit zone (to start an entry timer) and then entering an access
code or presenting a proximity tag to a keypad.
Note:
This method does not comply
with BS8243 clause 6.4.
Settle Time
This option is available only if
Exit Mode
is set to Final Door Set, Lock Set or Exit
Terminate. This option allows you to define a time delay to allow detectors to settle before
the system sets. During this period, the sounders stop and the control unit ignores any
alarms generated by the detectors.
Enter two digits to specify a time in seconds, from 01 to 30.
Confirm Set
This option is available only if
Exit Mode
is set to Instant Set. Selecting On causes an
audible confirmation beep at the end of the
Exit Time
. Selecting Off causes no audible
confirmation beep at the end of the
Exit Time
.