Maintaining the system
After installation, the system should be inspected once or twice per year as follows:
Check the control unit for obvious signs of damage to the case or its lid.
Check the action of the tamper switch.
Check, and if necessary, replace the standby battery.
Check keypads and other devices for obvious signs of damage.
Test the action of all buttons on all keypads.
Clean the surface and display of each keypad using a clean, soft, dry cloth. Do not
use water, solvents or any proprietary cleaning materials.
Where applicable, check cabling for signs of damage or wear.
Gently clean the lenses of any PIRs with a clean, soft dry cloth. Do not use water,
solvents or any proprietary cleaning materials.
Walk test all detectors.
Test any external sounders and strobes.