![Eaton PowerXL DM1 Series Installation Manual Download Page 26](http://html1.mh-extra.com/html/eaton/powerxl-dm1-series/powerxl-dm1-series_installation-manual_4136951026.webp)
16
Chapter 4—Mechanical installation
POWERXL SERIES VFDS
MN040060EN—September 2020 www.eaton.com
Table 16. Approximate space requirements in inches (mm).
Output rating
Mounting clearance imperial
Airflow
Input voltage Frame size
Drive
catalog
number
CT/IH
current
amps
VT/IL
current
amps
A
in. (mm)
B
in. (mm)
C
in. (mm)
D
in. (mm)
CFM (m3/h)
380 Vac to 480
Vac, 50/60 Hz
3-phase
FR1
DM1-341D5…
1.5
2.2
0
0
1.97 (50)
1.97 (50)
14.83 (25.2)
DM1-342D2…
2.2
4.3
0
0
1.97 (50)
1.97 (50)
14.83 (25.2)
DM1-344D3… 4.3
5.6
0
0
1.97 (50)
1.97 (50)
14.83 (25.2)
DM1-345D6… 5.6
7.6
0
0
1.97 (50)
1.97 (50)
14.83 (25.2)
FR2
DM1-347D6…
7.6
12
0
0
1.97 (50)
1.97 (50)
37.43 (63.6)
DM1-34012…
12
16
0
0
1.97 (50)
1.97 (50)
37.43 (63.6)
DM1-34016…
16
23
0
0
1.97 (50)
1.97 (50)
37.43 (63.6)
FR3
DM1-34023..
23
31
0
0
1.97 (50)
1.97 (50)
58.61 (99.6)
FR4
DM1-34031…
31
38
0
0
1.97 (50)
1.97 (50)
57.56 (97.8)
DM1-34038…
38
46
0
0
1.97 (50)
1.97 (50)
57.56 (97.8)
525 Vac to 600
Vac, 50/60 Hz
3-phase
FR2
DM1-354D5… 4.5
7.5
0
0
1.97 (50)
1.97 (50)
37.43 (63.6)
DM1-357D5…
7.5
10
0
0
1.97 (50)
1.97 (50)
37.43 (63.6)
DM1-35010…
10
13.5
0
0
1.97 (50)
1.97 (50)
37.43 (63.6)
FR3
DM1-35013…
13.5
18
0
0
1.97 (50)
1.97 (50)
58.61 (99.6)
FR4
DM1-35018…
18
22
0
0
1.97 (50)
1.97 (50)
57.56 (97.8)
DM1-35022…
22
27
0
0
1.97 (50)
1.97 (50)
57.56 (97.8)
Note:
The dimension for A in the table 2 will change if the option cards are used.
(continued).