9 Appendix
9.1 Special technical data
168
DC1 Frequency Inverter
10/12 MN04020003Z-EN
www.eaton.com
9.1.2 DC1-S2
9.1.3 DC1-12
Size
Symbol
Unit
4D3
7D0
011
Rated operational current
I
e
A
4.3
7.0
10.5
Overload current for 60 s every 600 s at 50 °C
I
L
A
6.5
10.5
15.8
Apparent power at rated operation
230 V
S
kVA
1.71
2.79
4.38
240 V
1.79
2.91
4.57
Assigned motor rating
230 V
P
kW
0.37
0.75
1.1
HP
0.5
1
1.5
Power side (primary side):
Number of phases
single-phase or two-phase
Rated operating voltage
U
LN
V
200 V - 10 % - 240 V + 10 %, 50/60 Hz
(180 - 264 V ±0 %, 48 - 62 Hz ±0 %)
Input current
I
LN
A
6.0
9.3
14.0
Minimum braking resistance
R
B
Ω
47
Pulse frequency
f
PWM
kHz
16 (adjustable 4 – 32)
Efficiency
η
0.95
0.95
0.95
Size
FS1
FS1
FS2
Size
Symbol
Unit
2D3
4D3
7D0
7D0
011
015
Rated operational current (I
e
)
I
e
A
2.3
4.3
7.0
7.0
10.5
15
Overload current for 60 s every 600 s at 50
°C
I
L
A
3.45
6.45
10.5
10.5
15.7
22.5
Apparent power in rated operation 400 V
S
kVA
0.92
1.71
2.79
2.79
4.38
5.98
480 V
S
kVA
0.96
1.79
2.91
2.91
4.57
6.24
Assigned motor rating
400 V
P
kW
0.37
0.75
1.5
1.5
2.2
4.0
460 V
HP
0.5
1
2
2
3
5
Power side (Primary side)
Number of phases
three-phase
Rated voltage
U
LN
V
200 V - 10 % - 240 V + 10 %, 50/60 Hz
(180 - 264 V ±0 %, 48 - 62 Hz ±0 %)
Input current
I
LN
A
6.7
12.5
14.8
14.8
22.2
31.7
Minimum braking resistance
R
B
Ω
47
47
47
Pulse frequency
f
PWM
kHz
16 (adjustable 4 – 32)
Efficiency
η
0.96
0.96
0.96
0.96
0.96
0.96
Fan (device-internal, temperature-controlled)
✓
✓
✓
✓
✓
✓
Size
FS1
FS1
FS1
FS2
FS3
FS3