6 Parameters
DC1 Frequency Inverter
10/12 MN04020003Z-EN
www.eaton.com
97
P-19
147
✓
rw
K1-Limit value (relay)
100.0
P-02 - 200.0 %
The adjustable limit value that is being used in connection with
settings 4 to 7 of P-18 and P-25
P-20
148
✓
rw
Fixed frequency FF1 / speed 1
0.0
P-10 = 0
→
-P-02 - P-01
→
Hz
P-10 > 0
→
-P-02 - P-01 x 60 s
→
rpm (1/min)
0.00 Hz (P-02) up to the maximum frequency value (P-01).
Activation via digital inputs depending on parameters P-12 and P-15
P-21
149
✓
rw
Fixed frequency FF2 / speed 2
0.0
P-10 = 0
→
-P-02 - P-01
→
Hz
P-10 > 0
→
-P-02 - P-01 x 60 s
→
rpm (1/min)
0.00 Hz (P-02) up to the maximum frequency value (P-01).
Activation via digital inputs depending on parameters P-12 and P-15
P-22
150
✓
rw
Fixed frequency FF3 / speed 3
0.0
P-10 = 0
→
-P-02 - P-01
→
Hz
P-10 > 0
→
-P-02 - P-01 x 60 s
→
rpm (1/min)
0.00 Hz (P-02) up to the maximum frequency value (P-01).
Activation via digital inputs depending on parameters P-12 and P-15
P-23
151
✓
rw
Fixed frequency FF4 / speed 4
0.0
P-10 = 0
→
-P-02 - P-01
→
Hz
P-10 > 0
→
-P-02 - P-01 x 60 s
→
rpm (1/min)
0.00 Hz (P-02) up to the maximum frequency value (P-01).
Activation via digital inputs depending on parameters P-12 and P-15
P-24
152
✓
rw
Second deceleration time (dec2)
0.0
0.1 - 25.0 s (
This parameter makes it possible to program an alternative decelera-
tion time, in the frequency inverter, that can be selected via digital
inputs (depending on the setting for P-15) or automatically in the event
of a mains power failure if P-05 = 2.
If the value is 0.00, the frequency inverter will coast all the way to a
stop.
PNU
ID
Access rights
Value
Description
DS
RUN
ro/rw
Summary of Contents for PowerXL DC1
Page 1: ...Manual PowerXL DC1 Frequency Inverter 10 12 MN04020003Z EN...
Page 4: ...II...
Page 12: ...0 About this manual 0 5 Units 8 DC1 Frequency Inverter 10 12 MN04020003Z EN www eaton com...
Page 190: ...9 Appendix 9 9 Sinusoidal filter 186 DC1 Frequency Inverter 10 12 MN04020003Z EN www eaton com...